DIP SWITCHES CONFIGURATIONS by PANEL CONTROL
DIP SWITCHES CONFIGURATIONS by PANEL
CONTROL
- Turn off the unit.
- Press the up ( ) and down ( ) buttons together
for 3 seconds to activate the dip switches
configurations by panel control (see Fig.4).
- See Table 1 for Dip Switches configurations and
functions by panel control.
NOTE: Press the up ( ) and down ( ) buttons
together for 3 seconds again or no operation
within 30 seconds to exit the dip switches
configurations by panel control and the unit will
save the last settings.
-
Display function settings with 2 digitals in LED
display window
, high (left) for dip switches,
low (right) for functions (see Fig.4).
- Press up ( ) button to set the dip swithces, press
down ( ) button to set the functons.
Fig.4
LED display window
Table 1 DIP SWITCHES CONFIGURATIONS by PANEL CONTROL
No .
Remarks
S1
For Heat Pump unit only
S2
S3*S9
S4*S5
S6
S7
SW7
You can consult with the sales
agency or manufacturer for details
S8
High(left)
0
/
1
2
3
4
6
7
8
A
Low(right)
1-by panel control
0-by dip switches
1-electric heat only
0-electric heat and pump heat
O
1-tmperature display in F
O
0-temperature display in C
3- use control panel or some types of wall t
2-use some types of wall thermostat; 1-use PT
AC other
wall thermostat; 0-control panel enable.
hermostat;
O O O O
3-61 F~86 F(16 C~30 C);
O O O O
2-65 F~78 F(18 C~26 C);
O O O O
1-63 F~80 F(17 C~27 C);
O O O O
0-68 F~75 F(20 C~24 C);
1-fan continuous run for heating
0-fan cycle for heating
1-fan continuous run for cooling
0-fan cycle for cooling
1-low temp. protection enable
0-low temp. protection disable
O O O O
4-62 F~86 F(17 C~30 C);
1-front desk control disable
0-front desk control enable
Not available for use PTAC
other wall thermostat .
NOTE:
1. The LED display window will show 00 when you first enter the setting mode, only when you set 01 you can start
the next settings.
2. To activate front dest control function, you need to pull the dip switch SW7 to DOWN(OFF) , and then set the panel
control to A0 .
3.
After all set, press up ( ) and down ( ) buttons together for 3 seconds to exit the operation interface and cut off the
power. When re-power on, the settings are activated.
Optional
Optional
High(left) Low(right)
Sw11
B
1-Load delay for 3 seconds
0-normal
01
Optional