Safety Instructions Please observe the following safety instructions to avoid personal injury and property loss. Do not operate any fan with a damaged cord or Plug. Do not move or adjust blower while in operation Keep this unit out of the reach of children Do not alter or modify your blower in any way. Only authorized Global Industrial replacement parts can be used.
Controls The blower Fan equip the Water proof 1 speed switch. Control Fan with the Switch 1- Turn on the Fan 0- Turn off the Fan Two 120-Volt Outlets for accessories and multi-fan connections. To reset, unplug the appliance causing the breaker to trip and push the Reset Button adjacent to the outlets on the Fan. Power Outlet Circuit Switch Breaker Reset Button Maintenance 1) 2) 3) 4) 5) 6) 7) 8) Inspect the electrical cord and wiring for damage or discoloration before use.
Trouble Shooting 1) BLOWER DOES NOT TURN ON 2) 3) 4) BLOWER STARTS AND THEN TURNS OFF BLOWER VIBRATES BLOWER MAKES SCRAPING NOISES MOTOR MAKES NOISE, BUT BLOWER WON’T TURN ON 1) 2) Switch not turned on - in this case, ensure that the knob is in the correct position to turn the unit on Circuit breaker or GFCI has tripped - press ‘reset button before attempting to turn the unit on Cord or wires are loose or damaged - Inspect to ensure that cords and wires are tight and free of damage Faulty switch - Co