User Guide
8. How many operation modes available. How many Fan speeds available.
A. 2 modes available; Cooling Mode and Fan Mode
2 fan speeds available; High and Low
9. Are the Air Louvers manual or automatic power controlled
A. The Louvers are manually controlled
10. What is the recommended installation set up
A. Place unit is a Flat / Level and Dry surface.
Select an open area and leave at least 20 inches (50cm) space around the unit
The exhaust duct should not have any bends greater than 45*
11. How to store the unit during the off season
A. Drain the water from water tank by uncapping the lid and removing the rubber
plug from the drain port. After all the water has drained from the container, run unit on
Fan Mode for 2 hours to dry up the unit’s interior. Unplug the Power cord and exhaust
duct. Clean out the filters and reset them. Use the Factory provided bag to cover the
whole unit and store it in a dry place.
12. TROUBLE SHOOTING
Symptoms
Analysis of causes
Solutions
Unit not working
Is power plug or AC
outlet working?
Insert plug in a reliable
AC source
Is water full indicator
“FL” flashing on the
display screen (water tank
is full)
Turn OFF unit. Drain
water from water tank.
Re-start the unit.
Possible Time out
shutdown
There is a 3 minute
delay on re-start to
protect the life of
compressor
Unit / Compressor
comes ON very often
*Strong Sunlight falling
direct on unit.
*External Heat source too
close to unit
If possible move unit
from heat source
*Filter dirty.
*In-take / Out-take are
jammed or clogged
Inspect & clean dirt at
filter and inlet and
outlet; check system