Use and Care Manual

16
End of Season Storage
1. Screw off the drain cover, pull out the stopper to drain water completely.
2. Keep unit running in fan mode with half day to dry inside completely to prevent it from going mouldy.
3. Turn off the unit, pull out plug then wrap the power cord around the wire-winding pillar, insert the plug into the
universal fixing hole at the back panel of the unit, install the water plug and drain cap.
4. Remove the heat exhaust hose assembly, clean and keep it properly.
5. Pack the air-conditioner properly with soft plastic bag and put it in dry place with appropriate dust-proof measures,
and keep the unit away from children.
6. Take out the batteries from the remote control and keep it properly.
Note:
The tilt angle of unit must be less than 30
degrees.
Hold the exhaust hose assembly with both hands when removal.
Push the fasteners aside on exhaust air outlet using your thumbs, then pull out exhaust hose assembly.
Assure the unit is stored in a dry place. All accessories of the unit shall be prop erly protected together.
Troubleshooting
Please check unit and suggestions below before asking for professional service, but never dismantle or repair the unit
by yourself, it may cause harm to you and your property.
Trouble
Cause
Remedy
The unit fails to start up
Power supply failure
Connect the unit to a live socket and turn it
on.
Water-full and its indicator lighting
Drain the water stored in the unit.
Ambient temperature too low or too
high?
It is recommended to use this unit between
10-3550-95.
The room temperature is lower than
the set temperature in cooling mode.
Change the set temperature
Bad cooling effects
There is direct sunlight
Close the curtain
The doors and windows are open, the
room is crowded or there are other
heat sources
Close the door and window, remove other
heat sources, and add new air-conditioners
Dirty filter
Clean or replace the filter mesh
Air inlet or air outlet clogged
Remove the obstruction
High noise level
The unit is being placed at uneven
surface.
Put the unit at a flat and firm place (may
reduce noise)
The compressor does
not work
Initiation of overheat protection.
Wait until the temperature decrease, the unit
will re-start automatically
The remote control does
Too long distance
Bring the remote control close to the