SDS

Revision Date 25-Dec-2014
Page 4 of 11
Sensitivity to Mechanical Impact No.
Sensitivity to Static Discharge No.
Protective equipment and precautions for firefighters
As in any fire, wear self-contained breathing apparatus pressure-demand,MSHA/NIOSH (approved or
equivalent) and full protective gear.
Personal precautions, protective equipment and emergency procedures
Personal Precautions Avoid contact with skin, eyes or clothing. Ensure adequate
ventilation.Use personal. protective equipment as required. Evacuate
personnel to safe areas.
Other Information Refer to protective measures listed in Sections 7 and 8.
Environmental Precautions
Environmental Precautions Refer to protective measures listed in Sections 7 and 8.
Methods and material for containment and cleaning up
Methods for Containment Prevent further leakage or spillage if safe to do so.
Methods for cleaning up Pick up and transfer to properly labeled containers
Precautions for safe handling
Handling In case of rupture. Use personal protection equipment. Avoid contact
with skin, eyes or clothing.
Conditions for safe storage, including any incompatibilities
Storage Keep containers tightly closed in a dry, cool and well-ventilated place.
Incompatible Products Strong acids. Strong oxidizing agents. Strong bases.
Control parameters
Exposure Guidelines
Chemical Name ACGIH TLV OSHA PEL NIOSH IDLH
Lithium Cobalt Oxide
(CoLiO2)
12190-79-3
TWA: 0.02 mg/m3
Graphite
7782-42-5
TWA: 2 mg/m3
respirable fraction all
forms except graphite
fibers
TWA: 15 mg/m3 total dust
synthetic
TWA: 5 mg/m3 respirable
fraction
synthetic
(vacated) TWA: 2.5 mg/m3
respirable dust natural
(vacated) TWA: 10 mg/m3
total
dust synthetic
(vacated) TWA: 5 mg/m3
respirable fraction
synthetic
TWA: 15 mppcf natural
IDLH: 1250 mg/m3
TWA: 2.5 mg/m3
respirable dust
Copper
7440-50-8
TWA: 0.2 mg/m3 fume
TWA: 1
mg/m3 Cu dust and mist
TWA: 0.1 mg/m3 fume
TWA: 1 mg/m3 dust and
mist
IDLH: 100 mg/m3 dust,
fume and
mist
8. EXPOSURE CONTROLS/PERSO
NAL PROTECTION
6. ACCIDENTAL RELEASE MEASURES
7. HANDLING AND STORAGE