Instructions / Assembly

User Instruction
8
Figure 1 SPECIFICATIONS
Sides:72 in. /
182.9 cm
Top:48in. /
121.9cm
30,000 Btu/hr
11 inches water
column
INPUT
Propane Regulator
Pressure
Clearances to
combustible
surfaces
A self-contained LP-gas cylinder for use with this appliance must have a capacity of 20
lbs. and must be equipped with a Type 1 connector and an OP D (overfill protection
device). See Figure 1.
The LP-gas supply cylinder to be used must be constructed and marked in accordance
with the specification for LP- gas cylinders of the U.S. Department of Transportation (DOT)
or the National Standard of Canada, CAN/CSA-B339, Cylinder, Sphere and Tubes for the
Transportation of Dangerous Goods.
The cylinder supply system must be arranged for vapor withdrawal.
The cylinder used must include a collar to protect the cylinder valve.
This appliance shall be used only outdoors in a well-ventilated space and shall not be
used in a building, garage or any other enclosed space.
When this appliance is not is use, the gas must be turned off at the supply cylinder.
Storage of this appliance indoors is permissible only if the cylinder is disconnected and
removed from the appliance.
IMPORTANT SAFETY INFORMATION
WARNING
Cylinders must be stored outdoors in a well-ventilated area out of
the reach of children.
Disconnected cylinders must have threaded valve plugs tightly
installed and must not be stored in a building, garage or any other
enclosed areas.
Storing cylinders indoors or in poorly ventilated spaces outdoors
can result inserious bodily injury and/or death.
CSA (Canadian Standards Association) certified to ANSI
Z21.97•CSA 2.41- 2017 “ Outdoor Decorative Gas Appliances”.