Instructions / Assembly

Assembly Instruction
10
TROUBLE SHOOTING
POSSIBLE CAUSE CORRECTIVE ACTION
Disconnect fountain from power source, remove any
obstruction, and clean bowl and tubing.
a) Pump is not covered with water.
b) Pump or fountain is blocked.
c) Pump is not secured correctly
d) Pump is not electrically connected
e) Pump may be “air locked.”
Disconnect fountain from power source, pour out any
remaining water, and ensure the tubing in the reservoir is
tightly secured to the pump outlet.
Plug and unplug the pump several times to clear any air
that may have been trapped.
Add more water to the reservoir.
Check to make sure pump is plugged in and the outlet is
working.
1.If the pump fails to run:
POSSIBLE CAUSE CORRECTIVE ACTION
There is not enough water in the basin to
operate your fountain.
Check the water level to make sure the pump is
completely submerged, add enough water to reservoir.
2.If the pump “spews” or “burp”:
CORRECTIVE ACTION
a) Disconnect the power supply and then remove the pump front cover and impeller cover.
b) Use hand to grip the impeller, gently pull the impeller/rotor assembly out of the pump housing.
3.If abnormal loud noise is heard during operation:
c) Rinse the impeller/rotor assembly and the cavity with clean water. If breakage or surface
damage is found in the assembly contact your local retailer or our customer service for a part
replacement.