Specification
SHIPPING
DI
RECTIONS FOR USE
PRECAUTIONS
G
LD2
0XX
-
4
–
9
/11
product. Steel - Prime with the appropriate waterborne or 
solventborne metal primer. Galvanized Metal and Aluminum - 
Prime with the appropriate waterborne metal primer. 
PREVIOUSLY PAINTED SURFACES:  Wash to remove 
contaminants. Rinse thoroughly with water and allow to dry. Dull 
glossy areas by light sanding. Remove sanding dust. Remove loose 
paint. Prime bare areas with primer specified under NEW 
SURFACES. 
WARNING! If you scrape, sand, or remove old paint, you may 
release lead dust. LEAD IS TOXIC. EXPOSURE TO LEAD DUST 
CAN CAUSE SERIOUS ILLNESS, SUCH AS BRAIN DAMAGE, 
ESPECIALLY IN CHILDREN. PREGNANT WOMEN SHOULD 
ALSO AVOID EXPOSURE. Wear an NIOSH-approved respirator 
to control lead exposure. Clean up carefully with a HEPA 
vacuum and a wet mop. Before you start, find out how to 
protect yourself and your family by contacting the National Lead 
Information Hotline at 1-800-424-LEAD or log on to 
www.epa.gov/lead.
TINTING:  Tint the appropriate base with universal colorants. 
SPREADING RATE: Apply at 300-400 sq ft/gal (7-10 m
2
/L). Actual 
coverage may vary depending on substrate and application method. 
Deeper shades of yellow, orange, pink, red and other colors may 
require multiple coats. 
APPLICATION: Mix thoroughly before use. May be applied by 
brush, roller or airless spray. Standard roller application should be 
used for best results. No thinning required. For airless spray, use a 
.015”-.019” tip at 2000 psi, adjust pressure as needed. For best 
touch-up results with airless spray, backroll airless spray area and 
touch-up with a standard roller. Application by conventional spray is 
not recommended. Two coats are required for new and uncoated 
surfaces. An additional coat may be necessary for dramatic color 
changes, dark colors or over rough surfaces for optimal appearance 
and hide. Do not apply when the surface or air temperature is below 
50ºF (10ºC). Provide good ventilation and warmth for normal drying. 
DRYING TIME: At 77ºF (25ºC) and 50% R.H., dries to touch in 30-
60 minutes and to recoat in four hours. Low temperature, high 
humidity, thick films or poor ventilation will increase these times. 
CLEAN-UP: Clean hands and tools immediately with warm, soapy 
water. Clean spills right away with a damp cloth. 
WASHING INSTRUCTIONS:  After 30 days or when paint has 
fully cured, areas may be washed using a non-abrasive, mild 
detergent solution and cellulose sponge. 
WARNING!
 CAUSES EYE, SKIN AND RESPIRATORY TRACT IRRITATION. MAY BE HARMFUL IF SWALLOWED. WHEN TINTED, CONTAINS 
ETHYLENE GLYCOL AND DIETHYLENE GLYCOL. ETHYLENE GLYCOL CAN CAUSE SEVERE KIDNEY DAMAGE WHEN INGESTED AND HAS 
BEEN SHOWN TO CAUSE BIRTH DEFECTS IN LABORATORY ANIMALS. DIETHYLENE GLYCOL MAY CAUSE CENTRAL NERVOUS SYSTEM 
EFFECTS AND LIVER, KIDNEY DAMAGE. USE ONLY WITH ADEQUATE VENTILATION! KEEP OUT OF THE REACH OF CHILDREN. For emergency 
information call (800) 545-2643. Note: These warnings encompass the product series. Prior to use, read and follow product-specific MSDS and label information. If 
sanding, wear a dust mask to avoid breathing of sanding dust. Do not breathe vapors or spray mist. Ensure fresh air entry during application and drying. Avoid contact with eyes 
and skin. If you experience eye watering, headaches, or dizziness, leave the area. If properly used, a respirator may offer additional protection. Obtain professional advice before 
using. Close container after each use. FIRST AID: For skin contact, wash thoroughly with soap and water. If any product remains, gently rub with petroleum jelly, vegetable or 
mineral/baby oil then wash again with soap and water. Repeat as needed. Remove contaminated clothing. For eye contact, flush immediately with plenty of water for at least 15 
minutes.  Get medical attention. If swallowed, get medical attention immediately. If inhalation causes discomfort, remove to fresh air. If discomfort persists or breathing 
difficulty occurs, get medical attention. KEEP FROM FREEZING.                 DS396-0211 
FREIGHT CLASSIFICATION: 
Paint, Freezable 
PACKAGING: 
1 gallon (3.785 L) 
5 gallon (18.925 L) 
FLASH POINT: 
None 
SURFACE PREPARATION
GENERAL SURFACE PREPARATION: All surfaces must be 
sound, dry, clean and free of oil, grease, dirt, rust, mildew, form 
release agents, curing compounds, loose and flaking paint and other 
foreign substances. Glossy surfaces must be dulled by sanding to 
ensure proper adhesion. Remove sanding dust. Fill all cracks and 
nail holes with spackle and spot prime with this product. For best 
results, prime heavily stained areas or watermarks with a stain 
blocking primer. 
NEW SURFACES: Drywall - Joint compound must dry for two 
days before priming. Dust clean. Prime new drywall with this 
product. Concrete, Masonry and Plaster - Cure at least 30 
days before painting. pH must be 10.0 or lower. Roughen slick 
poured or precast concrete and remove sealers by chemical cleaning 
or abrasive method such as sandsweeping. Rinse thoroughly with 
water and allow to dry. Must be internally dry. Remove loose 
aggregate. Prime any bare areas with this product. Fill concrete 
block with a latex block filler. Wood - Set nails, fill with latex 
spackle. Sand smooth. Dust clean. Prime bare wood with this 
Page 2 of 2