Datasheet

GE-O1602F-YYH-AT/R page 16/23 07.07.2011
11. Reliability
Content of Reliability Test (wide temperature, -20°C~70°C)
Note1: No dew condensation to be observed.
Note2: The function test shall be conducted after 4 hours storage at the normal
Temperature and humidity after remove from the test chamber.
Note3: Vibration test will be conducted to the product itself without putting it in a container.
Environmental Test
Test Item Content of Test Test Condition
Not
e
High Temperature
storage
Endurance test applying the high storage
temperature for a long time.
80
200hrs
2
Low Temperature
storage
Endurance test applying the high storage
temperature for a long time.
-30
200hrs
1,2
High Temperature
Operation
Endurance test applying the electric stress (Voltage
& Current) and the thermal stress to the element for
a long time.
70
200hrs
Low Temperature
Operation
Endurance test applying the electric stress under low
temperature for a long time.
-20
200hrs
1
High Temperature/
Humidity Operation
The module should be allowed to stand at
60,90%RH max
For 96hrs under no-load condition excluding the
polarizer,
Then taking it out and drying it at normal
temperature.
60,90%RH
96hrs
1,2
Thermal shock
resistance
The sample should be allowed stand the following
10 cycles of
operation
-20 25 70
30min 5min 30min
1 cycle
-20/70
10 cycles
Vibration test
Endurance test applying the vibration during
transportation and using.
Total fixed amplitude :
1.5mm
Vibration Frequency :
10~55Hz
One cycle 60 seconds
to 3 directions of X,Y,Z
for 15 minutes each
3
Static electricity test
Endurance test applying the electric stress to the
terminal.
VS=800V,RS=1.5kΩ
CS=100pF
1 time