Cooler inStallation CheCkliSt
Is the unit evenly and solidly supported, either upon legs, or flat on the base; check for high spots?
If the optional legs included, are they attached?
Is the unit level at the base, from end to end?
Do the doors open and close freely, without touching any other part of the unit in travel?
Are there open holes to the outside of the cabinet which are not plugged or insulated?
Are there obstructions of any kind to air flow into or out of the condensing unit?
Is product tubing or are other lines installed in such a manner to not allow shelf access?
inStallation
eleCtriCal and reFrigeration SpeCiFiCationS
eleCtriCal reFrigerant preSSure p.S.i.g.
type Charge high loW
FV24 120V, 1 phase, 60 Hz.
2.15 full load amps, 1/10 HP R134a 8.5 oz 220 115
FV48 120v, 1 phase, 60 Hz.
3.25 full load amps, 1/6 HP R134a 9.0 oz 220 115
eleCtriCal reFrigerant preSSure p.S.i.g.
type Charge high loW
MFV24 120V, 1 phase, 60 Hz.
5.0 full load amps, 1/5 HP R404A 10.0 oz 410 174
MFV48 120v, 1 phase, 60 Hz.
5.5 full load amps, 1/5 HP R404A 10.0 oz 425 174
FV24 and FV48
MFV24
and MFV48