Owner's manual

6
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com
eleCtriCal aNd refrigeratioN SPeCifiCatioNS
lP60, lP84, lP108 modelS
eleCtriCal refrigeraNt PreSSure P.S.i.g
120V, 1 phase, 60 Hz, 6.5 full load amps, 1/4 HP tyPe R134a, Charge 16.0 oz. high 350, low 88
wiriNg diagram
Green
C
Overload
Blue
1
2
3
46
7
8
9
Orange
Orange
Blue
Mate
N' Lock
Transformer
Compressor
Black
Green
White
Blue
White
Blue
White
White
Fans Per
Unit Varies
Lights Per
Unit Varies
12 VDC
120/240VAC 50/60HZ
Digital Controller
Self Contained
Units Only
Orange
Blue
Orange
Self-
Contained
Unit
Evaporator
Cond Fan
White
Start Capacitor
Start Relay
Optional
230VAC 50/60HZ 1 PH
Blue
White
Evap Fan
Evap FanSwitch
Lights
Temp Probe
White
R
S
Supply
Power Supply
120VAC 60HZ 1PH
1
2
3
46
7
8
9
Red
Temp Probe
Supply
White
Blue
Controller supply wires
will be jumpered to the
main controller by
matching numbers
Mate
N' Lock
Blue
White
+
-
Blower Motors
Wine Chiller
Controller
Blowers per
unit varies
Optional Beer Tower
Blower Package
Optional Wine
Chiller Package
Wiring For
Optional Packages
Red