PREVENTIVE MAINTENANCE SCHEDULE
Daily Syrup Tank When Cleaning Tanks
Connectors Rinse Both Quick Connects
In Clean Warm Water.
Daily Dispensing Wash Nozzle And Diffuser
Valves In Warm Soapy Water And
Rinse In Warm Water
Daily Dispensing Wash With Mild Detergent
Towers And Warm Water, Then
Wipe Dry. Flush Drain
With Warm Water
Twice Weekly Dispensing Follow Standard Brixing
Tower Brix Instructions
Check
Weekly Remote Cooler Wash With Mild Detergent
And Wipe Dry
Weekly System Review Pressure Gauges
Pressures For Proper Settings
Monthly Remote Cooler Clean Condenser With A
Air Cooled Soft Bristled Brush Or
Condenser Vacuum Cleaner
Every 6 Months Syrup Lines Follow “SANITIZING
SYRUP CIRCUITS”
Instructions
Every 6 Months Water Lines Follow “SANITIZING
WATER CIRCUITS”
Every 6 Months Water Bath Follow “WATER BATH
DRAINING AND CLEANING”
Instructions
Every 6 Months Lubrication Lubricate Circulating And
Carbonator Pump Coupling
With 3-5 Drops Of SAE 20
Non-Detergent Oil