User guide

Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com
5
lc47 sPecifications
LC47
StanDarD Features
• Modular lift-out refrigeration system for easy
in-field service
High capacity refrigeration and recirculation for
high volume and remote long distance installations
• CFC-free R134a refrigerant
Light-weight, roto-molded glycol bath with drain
• Polyurethane foamed-in-place insulation
NOTE: Clearance of 12” required around unit for
maximum air flow and 20” of overhead
clearance for servicing compressor.
Dimensions
Height - 34.56” (87.7 cm)
Width - 20.125” (51.1 cm)
Depth - 25.125” (63.8 cm)
Electrical
230V, 1 phase, 60 Hz, 12.4 full load amps
Dedicated 20 amp circuit is required
Includes a 8-foot grounded cord
Refrigeration
3/4 HP R134a lift-out medium temperature con-
densing unit
Glycol Bath Capacity
16.25 U.S. gallons (61.78 l)
Maximum Distance to Taps
400 ft (91.5 m)
Circulating Pump
60 gph (227 lph)
Circulating Motor
1/3 HP (.25 kW)
Shipping Weight
155 lbs (70.34 kg)
Operating Weight
273 lbs (123.87 kg)
Shipping Cube
12.75 cu ft (.36 cu m)
Options
Additional recirculating pump kit
4” Adjustable legs (up to 5-1/2”)
lc47 WirinG DiaGram
BLACK
BLACK
BLACK
BLACK
BLACK
COMPRESSOR
RECIRC MOTOR
OPTIONAL
RECIRC MOTOR
GREEN
MAIN POWER
SUPPLY
230v/60hz
CONDENSER FAN
TERMINAL BLOCK
TERMINAL BLOCK
TEMPERATURE CONTROL
RED
BLACK
GREEN
RED
BLACK
GREEN
M
MM
RED
RED
RED
RED
OVERLOAD
COMMON
RUN START
RELAY START