User guide

Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com
2
lc85 sPecifications
StanDarD Features
• Modular lift-out refrigeration system for easy
in-field service
High capacity refrigeration and recirculation for
high volume and remote long distance installations
• CFC-free R134a refrigerant
Light-weight, roto-molded glycol bath with drain
• Polyurethane foamed-in-place insulation
NOTE: Clearance of 12” required around unit for
maximum air flow and 20” of overhead
clearance for servicing compressor.
Dimensions
Height - 22.25” (56.5 cm)
Width - 26.75” (67.9 cm)
Depth - 16.50” (41.9 cm)
Electrical
115V, 1 phase, 60 Hz, 10.8 full load amps
230V, 1 phase, 50 Hz, 5.8 full load amps
Dedicated 15 amp circuit is required
Includes a 8-foot grounded cord
Refrigeration
1/3 HP R134a lift-out high temperature condensing unit
Glycol Bath Capacity
14.80 U.S. gallons (56.0 l)
Maximum Distance to Taps
125 ft (38.1 m)
Circulating Pump
60 gph (227 lph)
Circulating Motor
1/3 HP (.25 kW)
Shipping Weight
107 lbs (48.5 kg)
Operating Weight
225 lbs (102 kg)
Shipping Cube
9.5 cu ft (.28 cu m)
Options
4” Adjustable legs (up to 5-1/2”)
lc85 WirinG DiaGram
LC85
BLACK
BLACK
BLACK
BLACK
BLACK
TERMINAL BLOCK
OPTIONAL
RECIRC MOTOR
LC86 ONLY
RECIRC MOTOR
COMPRESSOR
OPTIONAL
RECIRC SWITCH
LC86 ONLY
RECIRC SWITCH
GREEN
RECEPTICAL
CONDENSER FAN
TEMPERATURE CONTROL
GREEN
MAIN POWER
SUPPLY
115v/60hz
M
M
M
WHITE
WHITE
WHITE
WHITE
RUN START
RELAY START
COMMON
OVERLOAD