9. trouble shootinG:
Complaints of warm beer...
Check the temperature of walk-in beer cooler.
Check the glycol bath temperature.
Check that recirculating pump is operating.
Refrigeration Compressor Will Not Run...
Check that the unit is getting electrical power.
Check that cold control is working.
Check that all wiring connections are secure.
Refrigeration Compressor Runs But Stops...
Check for dirt build-up on condenser coil surface.
Check that there is no obstruction of air flow into the cabinet.
Ensure that enough voltage is supplied to the unit.
Refrigeration Compressor Runs But Not Cooling...
Check for refrigerant leaks.
Noisy or Hot Recirculating Pump...
Ensure that glycol bath is not frozen.
Ensure that the glycol solution has been properly diluted.
Check motor and pump coupling for wear.
Recirculation Pump Not Working...
Ensure that pump and motor coupling has not worn free.
Check power supply to the motor.
Replace worn pump.