Operation Manual and Parts Directory LC65, LC85, LC86, LC44, LC47 Draft Pro Remote Glycol Line Chillers LC65 LC44 Glastender, Inc. · 5400 North Michigan Road · Saginaw, MI · 48604-9780 800.748.0423 · 989.752.4275 · Fax 989.752.4444 · www.glastender.com Rev. 02-05-14 © 2007 Glastender, Inc.
Index Topic Page Line Chiller Specifications and Wiring Diagrams.......................................1-5 LC65........................................................................................................ 1 LC85........................................................................................................ 2 LC86........................................................................................................ 3 LC44..................................................................
LC65 Specifications Dimensions • Height - 20.0” (49.5 cm) • Width - 18.0” (45.7 cm) • Depth - 25.75” (50.2 cm) Electrical • 115V, 1 phase, 60 Hz, 10.8 full load amps • 230V, 1 phase, 50 Hz, 5.8 full load amps • Dedicated 15 amp circuit is required • Includes a 8-foot grounded cord Refrigeration • 1/3 HP R134a lift-out high temperature condensing unit Glycol Bath Capacity • 7.5 U.S. gallons (28.4 l) Maximum Distance to Taps • 125 ft (22.9 m) Circulating Pump • 60 gph (227 lph) Circulating Motor • 1/3 HP (.
LC85 Specifications Dimensions • Height - 22.25” (56.5 cm) • Width - 26.75” (67.9 cm) • Depth - 16.50” (41.9 cm) Electrical • 115V, 1 phase, 60 Hz, 10.8 full load amps • 230V, 1 phase, 50 Hz, 5.8 full load amps • Dedicated 15 amp circuit is required • Includes a 8-foot grounded cord Refrigeration • 1/3 HP R134a lift-out high temperature condensing unit Glycol Bath Capacity • 14.80 U.S. gallons (56.0 l) Maximum Distance to Taps • 125 ft (38.
LC86 Specifications Dimensions • Height - 24.25” (61.6 cm) • Width - 26.75” (67.9 cm) • Depth - 16.50” (41.9 cm) Electrical • 115V, 1 phase, 60 Hz, 16.0 full load amps • 230V, 1 phase, 50 Hz, 8.0 full load amps • Dedicated 20 amp circuit is required • Includes a 8-foot grounded cord Refrigeration • 1/2 HP R134a lift-out high temperature condensing unit Glycol Bath Capacity • 14.80 U.S. gallons (56.0 l) Maximum Distance to Taps • 250 ft (53.
LC44 Specifications Dimensions • Height - 30.56” (77.6 cm) • Width - 20.125” (51.1 cm) • Depth - 25.125” (63.8 cm) Electrical • 115V, 1 phase, 60 Hz, 16.0 full load amps • 230V, 1 phase, 50 Hz, 8.0 full load amps • Dedicated 20 amp circuit is required • Includes a 8-foot grounded cord Refrigeration • 1/2 HP R134a lift-out high temperature condensing unit Glycol Bath Capacity • 16.25 U.S. gallons (61.78 l) Maximum Distance to Taps • 250 ft (53.
LC47 Specifications Dimensions • Height - 34.56” (87.7 cm) • Width - 20.125” (51.1 cm) • Depth - 25.125” (63.8 cm) Electrical • 230V, 1 phase, 60 Hz, 12.4 full load amps • Dedicated 20 amp circuit is required • Includes a 8-foot grounded cord Refrigeration • 3/4 HP R134a lift-out medium temperature condensing unit Glycol Bath Capacity • 16.25 U.S. gallons (61.78 l) Maximum Distance to Taps • 400 ft (91.5 m) Circulating Pump • 60 gph (227 lph) Circulating Motor • 1/3 HP (.
Remote Glycol Line Chiller Warranty Information Product Information Glastender, Inc.’s remote glycol line chillers are self-contained. Self-contained units have the compressor/ condensing unit mounted on the equipment and connected at the factory. Installation And Start-up The selling dealer is responsible for installation and start-up. Glastender, Inc. is not responsible for any installation or start-up costs. A. An “installation decal” with suggested guidelines is placed on each piece of equipment.
Remote Glycol Line Chiller Warranty Information G. The following are NOT considered “in-warranty”: 1. Materials and workmanship provided by the installer that cause part failure: (a) Plumbing - the installer is responsible for providing and hooking up glycol lines. (b) Electrical - The installer is responsible for providing necessary wiring and connections to the junction boxes or cord and plug provided. 2. Alterations from the original design that cause part failure. 3.
Inspection and Set-Up 1. Inspection Upon Arrival: Immediately upon arrival, a visual inspection of the carton should be made to determine if there is evidence of damage in shipment. Following uncrating, make an inspection for any signs of external damage. 2.
Glycol Filling and Unit Start-Up 5. Glycol Filling: The LC65 glycol bath capacity is 7.5 gallons (US). The LC85 and the LC86 glycol bath capacity is 14.8 gallons (US). The LC44 and LC47 glycol bath capacity is 16.25 gallons (US). Glycol supplied by Glastender, Inc. may be diluted to a ratio of (1) part glycol to (2) parts water for freeze protection down to 0ºF (-18ºC) or a ratio of (1) part glycol and (3) parts water for freeze protection down to 10ºF (-12ºC).
Cold Control Adjustment and System Start-Up 7. Cold Control Adjustment: Scale Adjusting Knob Cold Control 8. System Start-up: It is a good practice to operate the glycol recirculation system for sixty (60) minutes before running beer through to the remote dispensing station(s). This enables the glycol circuit to be checked for leaks. Also, recirculating cold glycol through the lines enables the temperature inside the trunk line to stabilize before beer is introduced.
Trouble Shooting 9. Trouble Shooting: Complaints of warm beer... • Check the temperature of walk-in beer cooler. • Check the glycol bath temperature. • Check that recirculating pump is operating. Refrigeration Compressor Will Not Run... • Check that the unit is getting electrical power. • Check that cold control is working. • Check that all wiring connections are secure. Refrigeration Compressor Runs But Stops... • Check for dirt build-up on condenser coil surface.
Typical Installation Detail 4 INSULATED LINE CONTAINING IN AND OUT GLYCOL LINES CO2 MAIN CO2 LINE FROM TANK MOUNT REGULATOR RUNS TO WALK-IN COOLER PRIMARY REGULATOR (STEP DOWN PRESSURE TO BELOW 60 POUNDS) SIDE ELEVATION OF BEER TOWER ON BAR TOP 2 RESTRICTION LINES ON TOWER ARE CONNECTED TO THE BEER LINE SET (DO NOT CHANGE LENGTH WITHOUT CONSULTING THE FACTORY) LINE CHILLER POWER TWO GLYCOL LINES GO THRU CHASE, SO GLYCOL CAN CIRCULATE BACK TO THE LINE CHILLER.
LC65 Compressor and Related Parts 11 6 19 10 1 2 3 7 8 4 9 17 18 5 14 12 15 16 13 13 Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780 800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.
LC65 Compressor and Related Parts Part No. Old Part No. Description 1. 06001439 2. 09000336 09000483 3. 09000299 4.
LC85 Compressor and Related Parts 9 18 11 2 4 1 7 3 19 16 17 5 6 15 12 8 13 10 14 15 Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780 800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.
LC85 Compressor and Related Parts Part No. Old Part No. Description 1. 2. 3. 4. 5. 06001439 09000336 09000483 09000299 09000463 GT-035014 GT-035109 GT-031537 GT-032805 GT-041306 6. 7. 8. 9.
LC86 Compressor and Related Parts 9 17 10 8 11 2 4 1 3 7 5 18 6 14 12 16 15 13 17 Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780 800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.
LC86 Compressor and Related Parts Part No. Old Part No. Description 1. 2. 3. 4. 5. 09000334 09000336 09000483 09000299 09000462 GT-035015 GT-035109 GT-031537 GT-032805 GT-041305 6. 7. 8. 9.
LC44 Compressor and Related Parts 19 7 11 12 8 17 10 9 3 2 15 16 4 14 6 13 18 1 19 5 Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780 800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.
LC44 Compressor and Related Parts 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. Part No. Old Part No.
LC47 Compressor and Related Parts 13 12 8 9 11 10 20 19 14 2 1 18 3 17 4 7 15 21 5 6 16 Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780 800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.
LC47 Compressor and Related Parts 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. Part No. Old Part No.
Remote Beer Line Chiller Accessories All Glastender line chillers may be placed on 4″ legs that are adjustable up to 5-1/2″. The leg set includes a 16 gauge galvanized steel frame plate that is sized to match the particular unit. LCLS-6 Line Chiller Leg Sets Model LCLS-6 LCLS-4 Description 4″ leg set and frame plate for LC65 4″ leg set and frame plate for LC44 and LC47 List $101 $111 Wgt 25# 33# A line chiller stand is 26-1/2″ wide by 39″ high by 24″ deep and comes with adjustable feet for leveling.
Installation Notes Installation Notes _________________________________________________________________________________________ _________________________________________________________________________________________ _________________________________________________________________________________________ _________________________________________________________________________________________ _________________________________________________________________________________________ _______________________