Owner's manual
2
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com
BLC speCifiCations
BLC-1/3-2
stanDaRD featuRes:
• Glycol connections with flared fittings for easy service access
• Durable black vinyl-clad exterior with 16 gauge galvanized steel base
• Stainless steel, CFC-free, foamed-in-place insulated glycol bath
• High efficiency heat exchanger minimizes glycol bath size to one gallon
• Front located glycol filling port
stanDaRD featuRes:
• Control panel is removable and includes wall bracket for remote installation
• Glycol connections with flared fittings for easy service access
• Durable black vinyl-clad exterior with 16 gauge galvanized steel base
• Stainless steel, CFC-free, foamed-in-place insulated glycol bath
• High efficiency heat exchanger minimizes glycol bath size to one gallon
• Front located glycol filling port
• Digital temperature control with LCD display
• Over-sized condenser coil for maximum efficiency
• Clear glycol bath cover for easy visual inspection
• Available with two recirculating pumps (designated by “-2” suffix in model number)
Dimensional and Specication Information
1/3 HP Beer Line Chiller
Model: BLC-1/3-E
1/3, 1/2, and 3/4 HP Beer Line Chillers with Remote Installable Control Panel
Models: BLC-1/3, BLC-1/3-2, BLC-1/2, BLC-1/2-2, BLC-3/4, BLC-3/4-2
BLC-1/3-E
Model No. BLC-1/3-E BLC-1/3 BLC-1/3-2 BLC-1/2 BLC-1/2-2 BLC-3/4 BLC-3/4-2
Dimensions† L e n g t h 27" 27" 27" 27" 27" 27" 27"
Width 21-1/4" 25-5/8" 25-5/8" 25-5/8" 25-5/8" 25-5/8" 25-5/8"
Height 14-3/4" 16" 16" 16" 16" 16" 16"
† Note: A minimum six inch clearance should be allowed around the entire unit for proper air ow.
Additional clearance should be considered above and in front of the unit for service access.
Electrical Voltage 120V 120V 120V 120V 120V 230V 230V
Frequency
60 Hz 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz
Phase 1ø 1ø 1ø 1ø 1ø 1ø 1ø
FLA 13 13 18.6 13.5 19.5 10.1 12.9
Dedicated
Circuit
20A 20A 30A 20A 30A 20A 20A
Electrical
Connection
Cord & Plug Cord & Plug
Hard Wire
Cord & Plug
Hard Wire Cord & Plug Cord & Plug
Refrigerant R134a R134a R134a R134a R134a R134A R134A
Refrigerant Charge 14 oz. 26 oz. 26 oz. 30 oz. 30 oz. 35 oz. 35 oz.
Compressor 1/3 HP 1/3 HP 1/3 HP 1/2 HP 1/2 HP 3/4 HP 3/4 HP
Capacities*
2,175 BTU/hr 2,175 BTU/hr 2,175 BTU/hr 3,300 BTU/hr 3,300 BTU/hr 6,375 BTU/hr 6,375 BTU/hr
* Note: Rated capacities assume maximum operating ambient temperature of 80°F.
Max Distance to Taps 125 ft. 125 ft. 125 ft. 250 ft. 250 ft. 400 ft. 400 ft.
Circulating Pumps 60 gph 60 gph 60 gph 60 gph 60 gph 60 gph 60 gph
Glycol Bath Capacity .94 gal .94 gal .94 gal .94 gal .94 gal .94 gal .94 gal.
Shipping Weight LBS (kg) 128 (58.1) 150 (68.0) 163 (73.9) 153 (69.4) 166 (75.3) 175 (79.5) 193 (87.7)