Operation Manual & Parts List A Family Company Manufacturing In The USA Since 1969 BLC-1/3-E, BLC-1/3, BLC-1/3-2, BLC-1/2, BLC-1/2-2, BLC-3/4, BLC-3/4-2 Remote Draft Beer Line Chillers BLC-1/3-E BLC-1/3-2 BLC-3/4-2 4004503 Conforms to UL STD 471 Certified to CAN/CSA STD C22.2 No. 120-M91 Glastender, Inc. · 5400 North Michigan Road · Saginaw, MI · 48604-9780 800.748.0423 · 989.752.4275 · Fax 989.752.4444 · www.glastender.com Rev. 07-15-14 © 2008 Glastender, Inc.
Index Beer Line Chiller Specifications................................................................................ 2 Inspection Upon Arrival............................................................................................ 3 Set-Up Remote Glycol Line Chiller.......................................................................... 3 Electrical Hook-Up.................................................................................................... 3 Glycol Line Connection....................
BLC Specifications 1/3 HP Beer Line Chiller Model: BLC-1/3-E Standard Features: • Glycol connections with flared fittings for easy service access • Durable black vinyl-clad exterior with 16 gauge galvanized steel base • Stainless steel, CFC-free, foamed-in-place insulated glycol bath • High efficiency heat exchanger minimizes glycol bath size to one gallon • Front located glycol filling port BLC-1/3-E 1/3, 1/2, and 3/4 HP Beer Line Chillers with Remote Installable Control Panel Models: BLC-1/3, BLC-1/3-
Inspection and Set-Up 1. Inspection Upon Arrival: Immediately upon arrival, a visual inspection of the carton should be made to determine if there is evidence of damage in shipment. Following uncrating, make an inspection for any signs of external damage. 2.
Glycol Filling and Start-Up 5. Glycol Filling: The glycol bath capacity is 1 gallon (US). Glycol supplied by Glastender, Inc. may be diluted to a ratio of (1) part glycol to (2) parts water for freeze protection down to 0ºF (-18ºC) or a ratio of (1) part glycol and (3) parts water for freeze protection down to 10ºF (-12ºC). These mix ratios are recommended, since the refrigeration system is not capable of lowering the temperature of the glycol bath below 15ºF (-9.
Temperature Control 8. Electronic Temperature Control Programming BLC-1/3, BLC-1/3-2, BLC-1/2, BLC-1/2-2, BLC-3/4, BLC-3/4-2 (NOTE: This control used on units prior to 11/21/2013 SN134147623X): The unit is shipped from the factory set at 26°F, differential set at 5, in C1, cooling mode. If reprogramming or adjusting is necessary follow these steps: Step 1 Press the SET key to start programming. Use the up or down arrow to toggle between and select F for degrees Fahrenheit or C for degrees Celsius.
Digital Controller Operation The operating temperature range is preset at the factory according to the table below and can be adjusted up or down within the limits shown. To see the set point - push and immediately release the SET button. The set point will be displayed. To return to normal visualization - Push and immediately release the SET button or wait five seconds. To change the set point - push and hold the SET button for more than two seconds.
BLC-1/3-E Wiring Diagram BLC-1/3, BLC-1/3-2 Wiring Diagram 7 Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780 800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.
BLC-1/2, BLC-1/2-2 Wiring Diagram BLC-3/4, BLC-3/4-2 Wiring Diagram Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780 800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.
Typical Installation Detail 9 Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780 800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.
Remote Control Panel Installation Detail Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780 800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.
Instructions For Control Panel Remote Installation The Glastender exclusive, patent pending beer line chiller design houses the heat exchanger inside the condensing unit compartment. For models BLC-1/3, BLC-1/3-2, BLC1/2, BLC-1/2-2, BLC-3/4, and BLC-3/4-2, this unique feature allows the control panel with glycol bath and recirculating pump(s) to be easily installed separately from the condensing unit in a more conveniently accessible location. Remove cabinet top and vented side to get at the power cord.
Remote Control Panel Installation Photo The Glastender exclusive, patent pending beer line chiller design houses the heat exchanger inside the condensing unit compartment. This unique feature allows the control panel with glycol bath and recirculating pump(s) to be easily installed separately from the condensing unit in a more conveniently accessible location. Simply remove the control panel from the condensing unit cabinet and mount it in the desired location.
BLC-1/3, BLC-1/3-2, BLC-1/2, BLC-1/2-2 Replacement Parts 13 3 7 6 4 1 5 12 2 9 16 17 11 10 15 8 14 13 Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780 800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.
BLC-1/3, BLC-1/3-2, BLC-1/2, BLC-1/2-2 Replacement Parts Part No. 1. 06001439 Description Price Compressor, 1/3 HP, R134a, 120V $435.00 09000481 Start capacitor for 1/3 HP R134a compressor (prior to 11/06/13 - SN 134147373) 10.00 06009616 Start capacitor for 1/3 HP R134a compressor (starting with and after 11/06/13 - SN 134147373) 20.00 09000479 Relay for 1/3 HP R134a compressor (prior to 11/06/13 - SN 134147373) 20.
BLC-3/4 & BLC-3/4-2 Replacement Parts 1 3 4 2 6 7 5 13 15 16 17 8 14 12 10 11 15 9 Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780 800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.
BLC-3/4 & BLC-3/4-2 Replacement Parts Part No. 1. 09000335 Description Price Compressor, 3/4 HP, R-134a, 120V 60hz $930.00 09000668 Start capacitor for 3/4 HP 220V compressor 31.00 09000670 Relay for 3/4 HP 220V compressor 35.00 09000671 Overload protector for 3/4 HP 220V compressor 13.00 2. 09000640 Condenser coil, 15 x 13 x 4 370.00 3. 08000085 Motor, 16 watt Condenser Fan 135.00 4. 09000528 Fan Blade, 10″ 17.00 5. 09000285 Filter Dryer, 1/4″ x 1/4″ 6. 09000286 Accumulator 126.
BLC-1/3-E Replacement Parts Part No. 1. 06001439 Description Price Compressor, 1/3 HP, R-134a, 120V $435.00 09000481 Start capacitor for 1/3 HP R-134a compressor, prior to 11/06/13 SN134147373 10.00 06009616 Start capacitor for 1/3 HP R-134a compressor, after 11/06/13 SN134147373 20.00 09000479 Relay for 1/3 HP R-134a compressor, prior to 11/06/13 SN134147373 20.00 06009614 Relay for 1/3 HP R-134a compressor, after 11/06/13 SN134147373 31.
Terms and Conditions Prices: All prices are LIST. Applicable taxes will be added. Quotations: Unless otherwise stated, quotations are effective for 30 days only. Acceptance: All orders are subject to acceptance by Glastender, Inc.’s headquarters in Saginaw, Michigan. Possession of the Product Directory and Price List is not an offer to sell. Shipments: F.O.B. factory in Saginaw, Michigan. Freight terms are Third Party or Collect if shipped directly to you.
Warranty Statement APPLICABLE TO ALL PRODUCTS SOLD WITHIN THE UNITED STATES AND CANADA LABOR: Glastender, Inc. warrants all products to be free of defects in material and workmanship. In established areas, a start-up is included with glasswasher models GT-24 and GT-30. A 1-year labor warranty applies to all glasswashers.
Trouble Shooting Complaints of warm beer... • Check the temperature of walk-in beer cooler. • Check the glycol bath temperature. • Check that recirculating pump is operating. Refrigeration Compressor Will Not Run... • Check that the unit is getting electrical power. • Check that cold control is working. • Check that all wiring connections are secure. Refrigeration Compressor Runs But Stops... • Check for dirt build-up on condenser coil surface.