Installation Guide
PART TWO – Install Hinge Panel
1. On the wall where the hinge panel is to be placed, mark a level vertical
line on the wall with a level. To get the placement of this line for the clips,
measure from return panel wall 31 13/16″ (Refer to Step 1 on illustration).
TIP: We recommend using a pencil so this can be easily removed.
2. Mark the center point for the two clips on the wall and one on the oor.
a. Top wall clip: measure 70 1/4″ from the oor along the vertical line.
b. Bottom wall clip: measure 7 3/4″ from the oor along the vertical line.
c. Floor Clip: measure out width of hinge panel subtract 3″ to get the
position of oor clip. Measure out 31 13/16″ from return panel wall
to get your exact oor clip placement (Refer to 2C on illustration).
3. Drill the holes for the clips.
a. Using a 1/4″ tile drill bit drill the 2 holes on wall and 1 hole on the oor.
NOTE: If you are xing oor clamp to a berglass shower base use a
1/8″ drill bit to pre-drill the hole rather than 1/4″ tile drill bit. You will not use
the green wall anchor but rather screw the clip directly to berglass base.
b. Insert the wall/oor anchors, you will need to hit these in with a hammer.
Be careful not to hit and break tile.
c. Place clip over holes and drill in screws to secure the clip.
Make sure these are securely fastened.
4. Set the hinge panel in place.
a. Place one 1/8″ rubber block provided on the ground 3″ from edge closest
to wall and one 1/16″ rubber block provided inside the oor clip.
b. Carefully place the hinge panel on the rubber blocks and slot the glass
into the wall clips.
IMPORTANT: The most fragile parts of the glass panels are the corners.
Therefore, it is critical you have the rubber blocks in place so the
glass never touches the tile surface you are installing onto.
5. Ensure the hinge panel is level. On the edge that will meet the door
panel, use a level to make sure the hinge panel is level and in line.
TIP: Use additional rubber blocks on either end of bottom of glass panel
to raise/drop the hinge panel if required to get level.
a. Check top of hinge panel and top of xed return panel are level (refer to
step 5a in illustration). If not level, adjust with rubber blocks under glass
panels. Once level, tighten the screws on the clips very tight.
b. Measure the remaining opening between the edge hinge panel and return
panel and this should be the width of door panel + 1/4″ at minimum so
the door will t.