Installation Guide

05
Set the fixed panel in place.
Place the ⅛" rubber block on the floor 3" from the wall.
Place the ⁄" rubber block inside the floor clip. Rubber
blocks are not required in the wall clips.
Carefully place the fixed panel on the rubber blocks and
slot it into the wall clips. Partially tighten screws.
Use a level on the outer-edge to ensure the fixed panel
is level and in line.
Important: There is stamp on the corner of all Glass Warehouse glass panels to certify it is tempered
safety glass. We recommend panels are installed with the stamp at the boom where it is less
noticeable. Note: the stamp is baked on during the tempering process and cannot be removed.
06
47⁄"
47⁄"
47⁄"
47⁄"
Measure and mark the hinge panel location.
Measure 47⁄" out from the fixed panel wall. This takes
you to the center line of the hinge panel location. Use a
level and mark a line up the wall and along the floor. This
is your center line for the wall clips.