User manual
8615 Touch Monitor
User’s Manual
2.2.7. VOLTAGE HOLD-UP TIME
When the power supply is operated at 100% of maximum continuous output
load, the minimum output holdup time after loss of input power shall be 8mS for
AC input voltage (115Vac, 60Hz) and at 60-degrees cut angle.
3. MECHANICAL REQUIREMENTS
3.1. PHYSICAL DIMENSIONS
The overall dimension of this switching power adapter is
108 mm (L) x 65 mm (W) x 31 mm (H) Max.
4. ENVIRONMENTAL REQUIREMENTS
4.1. TEMPERATURE AND HUMIDITY
Operating Temperature Range 10 ℃ to +40℃
Non-operating Temperature Range 0℃ to +85℃
Operating Humidity 10 to 90% relative humidity (non–condensing)
Non-operating Humidity 5 to 95% relative humidity (non–condensing)
4.2. VIBRATION AND SHOCK
The power adapter shall withstand forces of 2G at variable recurrent
frequencies of 20 to 30 Hz and a simulated transportation test. Transportation test
will consist of a 1/2G vibration force at the resonant frequencies of the board or
components.
The test will last for 15 min. The adapter will be tested in a configuration
representative of the intended application with shipping cartons. The adapter must
survive a 50G force for duration of 20 ms in all 3 orthogonal planes from normal
mounting points.
4.3. DROP TEST
The power adapter shall successfully comply with the following drop test
requirements: 6 random drops from a height of 70 cm onto concrete covered with
1/8 inch asphalt tile or similar material. No impairment of normal function,
breaking away of any parts or change that would render power adapter potentially
harmful shall occur.
50