User Manual
Table Of Contents
- Book 1: Setup & Maintenance
- Table of Contents
- Chapter 1
- Introduction
- Chapter 2
- Setting Up the System
- Setup Requirements
- Given Workstation
- DataRecorder and Cradle
- Storage Space for the PillCam Capsule Box
- Main Platform Components
- Connecting the Components
- Connecting the Given Workstation
- 1. Connect the Mouse cable to the Mouse connector.
- 2. Connect the Keyboard cable to the Keyboard connector.
- 3. Connect the monitor to the Workstation.
- 4. Connect the printer to the LPT connector or to the USB connector, depending on the printer’s connection cable.
- 5. If the Workstation’s voltage setting is manual, verify that the Workstation’s voltage matches the local voltage. If it does not, call Given Customer Support.
- 6. After voltage verification, connect the power cable of the Given Workstation to the electric outlet.
- 7. Connect the power cable of the monitor to the wall electric outlet.
- Connecting the DataRecorder Cradle
- Chapter 3
- Software Installation
- Chapter 4
- Multi-User Setup
- Chapter 5
- Technical Description
- System Labeling
- Essential Performance
- Warnings
- Cautions
- System Specifications
- PillCam SB Capsule
- PillCam SB 2 Capsule
- PillCam ESO 2 Capsule
- PillCam ESO 3 Capsule
- PillCam COLON 2 Capsule
- SensorArray DataRecorder 2
- SensorArray DataRecorder 3
- SB SensorBelt for DataRecorder 2 and DataRecorder 3
- DataRecorder 2 /2C
- Cradle DataRecorder 2
- DataRecorder 3
- Cradle DataRecorder 3
- DC Power Supply
- DataRecorder 3 Memory Card
- RAPID Software
- Guidance and Manufacturer's Declarations
- Chapter 6
- Maintenance
- Chapter 7
- Troubleshooting
PillCam Platform
36 Chapter 5
Capsule Labeling
Each box has a label at the bottom as shown below. Each capsule is marked with the expiration
date, lot number, and a unique Capsule ID code.
Essential Performance
PillCam Video Capsules
ON-Mode
Data transmitting to DataRecorder is considered to be essential performance of the PillCam
capsules. The PillCam capsules shall transmit data continuously monitored by on-line image
display as received by DataRecorder.
OFF-Mode
No unintentional transmissions are allowed.
DataRecorder 2 and DataRecorder 3
Data receiving by DataRecorder is considered to be essential performance of the DataRecorder 2
and DataRecorder 3.
Warnings
• PillCam Platform and its components need special precautions regarding EMC and need to be
installed and put into service according to the EMC information provided in the accompanying
documents.
• Portable and mobile RF communications equipment can affect the PillCam video capsule and
the DataRecorder.
Lot Number
Expiration Date
Capsule ID Code