User Manual
Table Of Contents
- Book 1: Setup & Maintenance
- Table of Contents
- Chapter 1
- Introduction
- Chapter 2
- Setting Up the System
- Setup Requirements
- Given Workstation
- DataRecorder and Cradle
- Storage Space for the PillCam Capsule Box
- Main Platform Components
- Connecting the Components
- Connecting the Given Workstation
- 1. Connect the Mouse cable to the Mouse connector.
- 2. Connect the Keyboard cable to the Keyboard connector.
- 3. Connect the monitor to the Workstation.
- 4. Connect the printer to the LPT connector or to the USB connector, depending on the printer’s connection cable.
- 5. If the Workstation’s voltage setting is manual, verify that the Workstation’s voltage matches the local voltage. If it does not, call Given Customer Support.
- 6. After voltage verification, connect the power cable of the Given Workstation to the electric outlet.
- 7. Connect the power cable of the monitor to the wall electric outlet.
- Connecting the DataRecorder Cradle
- Chapter 3
- Software Installation
- Chapter 4
- Multi-User Setup
- Chapter 5
- Technical Description
- System Labeling
- Essential Performance
- Warnings
- Cautions
- System Specifications
- PillCam SB Capsule
- PillCam SB 2 Capsule
- PillCam ESO 2 Capsule
- PillCam ESO 3 Capsule
- PillCam COLON 2 Capsule
- SensorArray DataRecorder 2
- SensorArray DataRecorder 3
- SB SensorBelt for DataRecorder 2 and DataRecorder 3
- DataRecorder 2 /2C
- Cradle DataRecorder 2
- DataRecorder 3
- Cradle DataRecorder 3
- DC Power Supply
- DataRecorder 3 Memory Card
- RAPID Software
- Guidance and Manufacturer's Declarations
- Chapter 6
- Maintenance
- Chapter 7
- Troubleshooting
Introduction
Chapter 1 11
DataRecorder 3 Screen Icons
The following icons appear in the top status line of the DataRecorder screen.
Battery and Capsule Icons
The following icons appear in the top status line of the DataRecorder screen.
Icon Explanation Icon Explanation
Start pairing procedure SensorArray not connected
Pairing succeeded DataRecorder is initialized
Data not downloaded
DataRecorder is waiting for
initialization
Data downloaded SensorArray failure
Wrong SensorArray type Small bowel detection
End procedure, Memory full
Regimen Reminder numbers
appear in status line when in Real
Time Viewing mode
Icon Battery Status Icon Capsule Reception Status
Battery fully charged Signal weak, recording with noise
Battery charge level at 10%
intervals
Signal strong, recording with
noise
Battery empty, DataRecorder
shuts down
Signal weak, but recording OK
Signal strong, and recording OK