User's Manual
Table Of Contents
- User Manual
- RAPID® v8.3
- Table of Contents
- Chapter 1
- Using This Guide
- Chapter 2
- Indications, Contraindications, Warnings, Cautions
- Chapter 3
- Welcome to PillCam Capsule Endoscopy
- Chapter 4
- Preparing for PillCam Capsule Endoscopy
- Preparing the Patient
- Preparing the Required Equipment
- Creating Patient Instructions for the Procedure
- General Patient Guidelines During the Procedure
- Performing Patient Check-in
- Fitting Equipment on the Patient
- Chapter 5
- Know Your PillCam Recorder
- Chapter 6
- Performing PillCam Capsule Endoscopy
- Chapter 7
- Creating RAPID Videos
- Chapter 8
- Reviewing and Interpreting RAPID Videos
- Loading a Study with the Study Manager
- Using the Study Manager
- Overview of the RAPID Interface
- Using RAPID to View a Video
- RAPID Video Files
- Working with Findings
- Creating a PillCam Capsule Endoscopy Report
- RAPID Atlas
- Lewis Score
- Generating a Report
- Appendix A1
- Installing RAPID Software
- Appendix A2
- Configuring RAPID Software
- Appendix A3
- PillCam Equipment Maintenance
- Appendix A4
- Troubleshooting
- Appendix A5
- Technical Description
- System Labeling
- Essential Performance
- Warnings
- Cautions
- System Specifications
- PillCam SB 2 Capsule
- PillCam SB 3 Capsule
- PillCam UGI Capsule
- PillCam COLON 2 Capsule
- Sensor Array PillCam Recorder DR2
- Sensor Array PillCam Recorder DR3
- PillCam Recorder DR2/DR2C
- Cradle PillCam Recorder DR2
- PillCam Recorder DR3
- PillCam Recorder DR3 SDHC Memory Card
- Cradle PillCam Recorder DR3
- DC Power Supply
- RAPID for PillCam Software
- Guidance and Manufacturer's Declarations
- Index
Preparing for PillCam Capsule Endoscopy
Fitting Equipment on the Patient 57
Before dispensing the PillCam capsule, the equipment must be prepared.
Attaching the Sensors to the PillCam Recorder
The PillCam recorder is worn by patients during the procedure in the recorder pouch with shoulder
strap or in the recorder belt with suspenders. Make sure that these accessories fit the patient
comfortably.
Recorder Pouch
To fit the recorder pouch:
1. With the patient standing, hang the recorder pouch from the patient’s shoulder as displayed in the
illustration.
2. Adjust the shoulder strap so that the recorder hangs at the patient's side at waist level with the
supplied strap securing the recorder to the waist.
֠
֠֠
֠
Note
Adjust the downlink loop to remove excess cable so that it fits closely to the
patient's body. To prevent damage to the wires do not forcibly bend the
downlink loop in any way.
!
Caution
• Make sure that there is no other PillCam capsule or other diagnostic
capsule in the patient’s gastrointestinal tract.
• Verify that the capsule expiration date has not passed (see the date next
to the icon on the packaging).
• If you are performing the procedure for the first time, read the capsule
package insert.