Data Sheet
LOW BATTERY
MUTE MODE
When Base unit is near the searched tag (all 5 LED lit up), turn the Base unit mute switch to OFF so the Tag unit
melody can be heard. Continue to follow the Base unit green LED lights until the Tag unit is found.
For search in a quiet environment: Set Base unit mute switch to OFF position before entering the search function.
Base and Tag units will turn-off alarm and enter the silent search mode.
All devices are registered before shipped; following procedure is just for your information.
Example for registering Tag 2.
1. To avoid the registration failure, make sure all Tag units and Base unit are powered off.
2. Press the setting button and search button 2 together. While still pressing the setting button and search button 2, turn
the power on the Base unit.
3. Keep pressing the setting button and search button 2 and wait for the red light above the search button 2 to flash
twice before releasing both buttons.
4. If you have successfully entered the registration mode for Tag 2, the light above search button 2 and below the
dis-alarm light on the Base unit will be flashing together.
5. Place the unregistered Tag unit close to the Base unit (no more than 3” or 10 cm away) and turn the Tag unit on.
6. If registration was successful, the Base unit will beep once you have turned on the Tag unit.
7. If you need to register Tag 3 and 4, repeat steps 1-6 for each Tag.
Important: The register process must follow the order from 1 to 4.
REGISTER TAGS
STANDBY MODE/SLEEP MODE
OUT OF RANGE (LOSS SIGNAL)
a.) After switching the Base unit and Tag unit to power on, the Base unit will enter the linking process. The connecting status
LED blinks while the Base unit is linking with the Tag unit in 5~10 seconds. If the Tag unit is within working range and NOT
being blocked and the Tag unit has been linked up, the Base and Tag units will enter the standby mode.
b.) In initialized phase: If the Base unit cannot link with the Tag unit due to out of range, blocked signal, or powered off Tag, it
will enter sleep mode and continue to re-try to link the Tag unit. When user has found an unlinked tag (do not blink every
second), user can push the Search key to enter the link-up process instantly.
c.) When Base and Tags are linked, they will go to standby mode and connecting status LED will blink every second to
show real-time linking activities.
Long Battery life Suggestion: When units are not in use, please turn off the Base and Tag units to conserve the
battery life.
a.) When devices are out of range or in the lost signal condition, the Base unit beeps, vibrates and signal LED blinks for 10
seconds. The Tag unit beeps for 15 seconds. The Base unit enters the sleep mode automatically and continues to try to
link to the Tag unit.
b.) Press the Search button on the Base unit to enter the linking-up process.
When the Base unit or Tag unit is under low battery condition, it will beep every 2 minutes. Please change the battery
immediately.
Important: Under low battery condition, it may cause abnormal function of alarm or searching.
ALERT MODE - Prevent Items From Lost
When the Base unit alarms and vibrates, it means that distance between the Base unit and the Tag unit is out of range
(Near, Middle, Far ) of the set Tag unit range. The alert function can be disabled by setting the Base unit to the
dis-alarm mode.
How to change the safety range (Default in Middle), example for Tag 1:
1. Hold the setting button. Red light for Tag unit 1and the zone it is
set in will flash.
2. If you would like to change the zone (Near, Middle, Far) setting,
press the search button for Tag 1 and change the safety range to
the desired range.
3. Repeat this process for Tag 2, 3 and 4 if you have multiple Tags.
Page 3
ACTIVATING PANIC ALERT
Tag provides the additional function of enabling a child or dependent in need to activate an alert alarm to call for help.
To activate the Panic alarm, simply press and hold the panic button on the Tag and the Base unit will vibrate and alarm
to which Tag has activated the Panic alarm.
GUARDIAN ANGEL USER MANUAL