Spec Sheet
Gillette Generators, Inc. •
••
• 2921 Thorne Dr. •Elkhart, IN • 46514 • Ph: 574-264-9639 • Fax: 574-262-1840 • Web: www.gillettegenerators.com • spc4-180810
1
60 HZ MODEL
SPJD-1550
LIQUID COOLED DIESEL ENGINE GENERATOR SET
GENERATOR RATINGS
GENERATOR
MODEL
VOLTAGE
PH HZ
120°
°°
°C RISE STANDBY RATING
POWER LEAD
CONNECTIONS
L-N L-L KW/KVA AMP
SPJD-1550-1-1
120 240 1 60 155/155 646 4 LEAD DEDICATED 1 PH
SPJD-1550-3-2
120 208 3 60 151/188.8 525 12 LEAD LOW WYE
SPJD-1550-3-3
120 240 3 60 151/188.8 455 12 LEAD HIGH DELTA
SPJD-1550-3-4
277 480 3 60 155/193.8 233 12 LEAD HIGH WYE
SPJD-1550-3-5
127 220 3 60 151/188.8 496 12 LEAD LOW WYE
SPJD-1550-3-16
346 600 3 60 155/193.8 186 4 LEAD DEDICATED 3 PH
RATINGS: All single phase gen-sets are dedicated 4 lead windings, rated at unity (1.0) power factor. All three phase gen-sets are 12 lead windings, rated at .8 power factor.
120° C “STANDBY RATINGS” are strictly for gen-sets that are used for back-up emergency power to a failed normal utility power source. This standby rating allows
varying loads, with no overload capability, for the entire duration of utility power outage. All gen-set power ratings are based on temperature rise measured by resistance
method as defined by MIL-STD 705C and IEEE STD 115, METHOD 6.4.4. All generators have class H (180°C) insulation system on both rotor and stator windings. All
factory tests and KW/KVA charts shown above are based 120°C (standby) R/R winding temperature, within a maximum 40°C ambient condition. Generators operated at
standby power ratings must not exceed the temperature rise limitation for class H insulation system, as specified in NEMA MG1-22.40. Specifications & ratings are subject
to change without prior notice.
Model
STANDBY
120ºC RISE
HZ
SPJD
-
1550
-
60 HERTZ
60 151/155
“OPEN” GEN-SET
There is no enclosure, so gen-set must be
placed within a weather protected area, un-
inhabited by humans or animals, with proper
ventilation. Silencer not supplied, as
installation requirements are not known.
However, this item is available as optional
equipment.
“LEVEL 2” HOUSED GEN-SET
Full aluminum weather protection and superior
sound attenuation for specific low noise
applications. Critical grade muffler is standard.
All generator sets are USA prototype built and thoroughly tested.
Production models are USA factory built and 100% load tested.
UL2200, UL1446, UL508, UL142, UL498
NFPA 110, 99, 70, 37
All generator sets meet NFPA-110 Level 1, when equipped with the
necessary accessories and installed per NFPA standards.
NEC 700, 701, 702, 708
NEMA ICS10, MG1, ICS6, AB1
ANSI C62.41, 27, 59, 32, 480, 40Q, 81U, 360-05
ASCE 7-05 & 7-10
All generator sets meet 180 MPH rating.
EPA 40CFR Part 60, 1048, 1054, 1065, 1068