Item Brochure

Gillette Generators, Inc.
2921 Thorne Dr. Elkhart, IN 46514 Ph: 574-264-9639 Fax: 574-262-1840 Web: www.gillettegenerators.com spc4-200226
3
COOLING SYSTEM
Type of System ................................ Pressurized, closed recovery
Coolant Pump ..................................... Pre-lubricated, self-sealing
Cooling Fan Type (no. of blades) ................................. Pusher (8)
Fan Diameter inches (mm) ........................................... 52" (1321)
Ambient Capacity of Radiator °F (°C) .......................... 125 (51.6)
Engine Jacket Coolant Capacity Gal (L) ........................ 9.5 (43.2)
Radiator Coolant Capacity Gal. (L) ........................... 50.0 (227.3)
Maximum Restriction of Cooling Air Intake
and discharge side of radiator in. H
2
0 (kpa) .................. 0.5 (.125)
Water Pump Capacity gpm (L/min) .............. ................ 180 (680)
Heat Reject Coolant: Btu/min (kw) .............. ........... 16,189 (284)
Low Radiator Coolant Level Shutdown………………...Standard
Note: Coolant temp. shut-down switch setting at 230°F (110°C) with 50/50
(water/antifreeze) mix.
AIR REQUIREMENTS
Combustion Air, cfm (m
3
/min) .................... ............... 635 (18.0)
Radiator Air Flow cfm (m
3
/min) ................... ........ 36,000 (1,019)
Heat Rejected to Ambient:
Engine: kw (btu/min) ............................. ............. 66.0 (3765)
Alternator: kw (btu/min) ........................ ................ 23 (1309)
EXHAUST SYSTEM
Exhaust Outlet Size .............................................................. (2) 5"
Max. Back Pressure, in. hg (KPA). ................................ 3.0 (10.2)
Exhaust Flow, at rated kw: cfm (m
3
/min) ..... ..... ……2521 (71.3)
Exhaust Temp., at rated kw: °F (ºC) ……………..….1382 (750)
Engines are EPA certified for Natural Gas.
Deep Sea 7420
The 7420 controller is an
auto start mains (utility)
failure module for single
gen-set applications. This
controller includes a backlit
LCD display which
continuously displays the
status of the engine and
generator at all times.
The 7420 controller will also monitor speed, frequency,
voltage, current, oil pressure, coolant temp., and fuel levels.
These modules have been designed to display warning and shut
down status. It also includes: (11) configurable inputs (8)
configurable outputs voltage monitoring mains (utility)
failure detection
SOUND LEVELS MEASURED IN dB(A)
Open Level 2
Set Encl.
Level 2, Critical Silencer ......................... 94............ ........... 80
Level 3, Hospital Silencer ........................................ ........... 75
Note: Open sets (no enclosure) has (2) optional silencer system choices
due to unknown job-site applications. Level 2 enclosure has installed
critical silencer with upgrade to hospital silencer. Sound tests are
averaged from several test points and taken at 23 ft. (7 m) from source
of noise at normal operation.
DERATE GENERATOR FOR ALTITUDE
3% per 1000 ft.(305m) above 3000 ft. (914m) from sea level
DERATE GENERATOR FOR TEMPERATURE
2% per 10°F(5.6°C) above 104°F (40°C)
DIMENSIONS AND WEIGHTS
Open Level 2
Set Enclosure
Length in (cm) ......................... 152 (368) ..... ................ 186 (473)
Width in (cm) ........................... 72 (183) ...... ................. 72 (183)
Height in (cm) .......................... 80 (203) ...... ................. 94 (239)
3 Ø Net Weight lbs (kg) ........ 8625 (3912) ... .......... 11125 (5047)
3 Ø Ship Weight lbs (kg) ...... 8975 (4071) ... .......... 11475 (5205)
(250) event logs configurable timers automatic shutdown or
warning during fault detection remote start (on load) engine
preheat advanced metering capability hour meter text LCD
displays protected solid state outputs test buttons for:
stop/reset manual mode auto mode lamp test start button
power monitoring (kWh, kVAr, kVAh, kVArh)This controller
includes expansion features including RS232, RS484 (using
MODBUS-RTU/TCP), direct USB connection with PC,
expansion optioned using DSENet for remote annunciation and
remote relay interfacing for a distance of up to 3300FT. The
controller software is freely downloadable from the internet and
allows monitoring with direct USB cable, LAN, or by internet
via the built in web interface.
APPLICATION AND ENGINEERING DATA FOR MODEL SP-3500-60 HZ
DEEP SEA 7420 DIGITAL MICROPROCESSOR CONTROLLER
LOW LOAD CONDITIONS: Operation of PSI HD engines at low-load conditions should be limited to no more than one (1) hour per twenty-four (24) hour
period. If the application requires extended time at light loads, it is recommended that the engine load be increased to at least 70% of mechanical rating for a
minimum of two (2) hours per fifty (50) hours of low-load operation. Piston sealing rings rely on adequate cylinder firing pressure and temperature to seal the
combustion chamber and prevent excessive engine oil from entering the power cylinder. Under low loads these rings will not seal properly, resulting in oil being
burned in the combustion chamber and carbon deposits on pistons and valves. This mechanism is well-documented in reciprocating engines of all fuel types
and is often referred to as “wet-stacking.”