Owner's manual

“b” Time Code:
This command toggles through the four possible time
codes:
LaserDisk (or DVD)
Smpte
Internal time base
External time base
“c Brick Start:
This command is used to select where in the memory
of the Smart Bricks the show will start. Valid entries are
made in up to seven decimal numbers, ranging from 0
to 1,048,575. If you are using a 16K Smart Brick, the
upper limit should be below 16,383. If using a 64K Smart
Brick, the limit should be kept below 65,535 frames. The
Rack Smart Brick Brain will automatically translate this
number in to a ‘time’ value and display it next to the
number you have entered. The BRICK START is also sub-
tracted from the BRICK END time so that the show length
is also displayed.
“d Brick End:
This command is used to select where in the memory
of the Smart Brick the show will end if using Smpte,
Internal or external clocking. Valid entries are made in
up to seven decimal numbers, ranging from 0 to
1,048,575. If using a 64K Smart Brick, the limit should be
kept below 65,535 frames. The Rack Smart Brick Brain will
automatically translate this number in to a ‘time’ value
and display it next to the number you have entered. The
BRICK START is also subtracted from the BRICK END time
so that the show length is also displayed.
e At End of this Show:
This command allows you to toggle between four dif-
GILDERFLUKE & CO .205 SOUTH FLOWER STREET BURBANK , CALIFORNIA 91502 818/840-9484 800/776-5972 FAX 818/840-9485
E
AST COAST /FLORIDA OFFICE 7041 GRAND NATIONAL DRIVE SUITE 128d ORLANDO , FL. 32819 407/354-5954 FAX 407/354-5955
86 of 178