- Disabling the Outputs When Stopped -
This jumper plug must be installed for the Smart Brick to work. It
has two possible positions. This position will cause all of the out-
puts to turn off whenever the Smart Brick System stops advancing
frames and the ‘running delay’ counter has run out. This is useful
if damage might result from leaving certain outputs in your sys-
tem turned on indefinitely, as could occur if the system were
stopped while those outputs were active.
0
channel
U8
1
channel
U7
2
channel
U6
3
channel
U5
U14 (ch 0)
U13 (ch 1)
U12 (ch 2)
U11 (ch 3)
JP3
JP2
DMX-
512
in/out
DMX-512 Address
DMX
heart
Brain heart
DMX data
DMX Error
U17 26LS32
JP6
DMX-512
Forever!
Yes No
GILDERFLUKE & CO .205 SOUTH FLOWER STREET BURBANK , CALIFORNIA 91502 818/840-9484 800/776-5972 FAX 818/840-9485
E
AST COAST /FLORIDA OFFICE 7041 GRAND NATIONAL DRIVE SUITE 128d ORLANDO , FL. 32819 407/354-5954 FAX 407/354-5955
19 of 178