Instruction Manual

value), ‘4’ (set the value to 50%), and ‘1’ (decrease the value)
keys.
b) The ‘Maximum Scale’ endpoint is set using the ‘8’ (increase the
value), ‘5’ (set the value to 50%), and ‘2’ (decrease the value)
keys.
c) The ‘Forced Outputs’ is set using the ‘9’ (increase the value), ‘6’
(set the value to 50%), and ‘3’ (decrease the value) keys. When
this value has been disabled, it will appear as a ‘n/a’ on the
command line. The ‘Forced Outputs’ can be used to move a
figure when a Togglodyte or other source of DMX-512 data is
not available.
The current values for these variables are displayed on the com-
mand line as they are changed. When you have finished making the
adjustments, hitting the <space bar>, <Enter key> or <Return Key>
will save write these variables to the EEprom and display them on the
table on the main part of the screen.
The basic object when you are setting the endpoints for a move-
ment are 1) to command the movement to one extreme and then
set that endpoint to where you want it, and 2) command the move-
ment to the opposite endpoint and then set it.
To set the endpoints for any output, just follow these simple steps:
1) Select the output you want to adjust: You can do this
using the j) Output to Test & Adjust’, ‘n) Next’ or ‘l) Last
commands. The output must be one of the on-board
ones. The arrow will now be pointing at the output you
are going to adjust.
2) Select this command by typing ‘u’: The current values
will now appear on the command line.
3) Set the output to either one of the extremes of posi-
tion:
a) If you have a programming system or Togglodyte
attached: Just set the output to either the mini-
mum position (0%/0/00h) or maximum position
(100%/255/0FFh).
2
b) If you only have the computer: Use the ‘3’, ‘6’ and
‘9’ keys on your keypad to force the movement to
either the minimum position (0%/0/00h) or maxi-
GILDERFLUKE & CO.205 SOUTH FLOWER STREET BURBANK, CALIFORNIA 91502 818/840-9484 800/776-5972 FAX 818/840-9485
E
AST COAST /FLORIDA OFFICE 7041 GRAND NATIONAL DRIVE SUITE 128d ORLANDO , FL. 32819 407/354-5954 FAX 407/354-5955
17 of 22
2
These are the eight bit resolution values. Substitute the twelve bit equiva-
lents of 100%/4095/FFFh if you are using twelve bit resolutions.