Gilderfluke & Co.• 205 South Flower Street • Burbank, California 91502 • 818/840-9484 • 800/776-5972 • fax 818/840-9485 Lg-DMX/DC DMX-512 to DC Dimmer Module v3.0 The Lg-DMX/DC is a complete DC in to DC out dimmer module. All you need to add is a 9-24 VDC power supply, whatever you want to control, and a source of DMX-512 to control it. The Lg-DMX/DC can be used to control incandescent lamps, large LED arrays or DC motors.
Gilderfluke & Co.• 205 South Flower Street • Burbank, California 91502 • 818/840-9484 • 800/776-5972 • fax 818/840-9485 Safety Disclaimer: Any electronic or mechanical system has a potential to fail. Certain applications using Gilderfluke & Company equipment may involve potential risks of death, personal injury, or severe property, or environmental damage (“Critical Application”).
Gilderfluke & Co.• 205 South Flower Street • Burbank, California 91502 • 818/840-9484 • 800/776-5972 • fax 818/840-9485 Lg-DMX/DC Overview ........................................................................... 5 Features of the Lg-DMX/DC include:!................................................................. 5 Lg-DMX/DC ‘Test’ Button ..................................................................... 6 On each sequential push of the ʻTestʼ button:!................................................
Gilderfluke & Co.• 205 South Flower Street • Burbank, California 91502 • 818/840-9484 • 800/776-5972 • fax 818/840-9485 A note about this manual: This manual covers the specifics of the Lg-DMX/DC. Information and manuals for all other Gilderfluke & Company products can be downloaded from our web site at: http://www.gilderfluke.
Gilderfluke & Co.• 205 South Flower Street • Burbank, California 91502 • 818/840-9484 • 800/776-5972 • fax 818/840-9485 Lg-DMX/DC Overview The Lg-DMX/DC can be used to control any low voltage Direct Current (DC) load from a DMX-512 serial control signal. The DMX-512 can come from a Br-Brain4, Br-ANA, Br-miniBrick8, Sd-50/8, Sd-50/8 or any other Gilderfluke & Company card which transmits animation and lighting data through DMX-512.
Gilderfluke & Co.• 205 South Flower Street • Burbank, California 91502 • 818/840-9484 • 800/776-5972 • fax 818/840-9485 Lg-DMX/DC ʻTestʼ Button The ‘Test’ button is used to manually turn on and off the outputs of the Lg-DMX/DC to test for wiring problems or check for burnt out lamps. Each time the ‘test’ button is pressed, it advances to the next test. If DipSwitch 4 is ‘Off’, then all outputs will be turned off while any of the outputs are ‘under test’.
Gilderfluke & Co.• 205 South Flower Street • Burbank, California 91502 • 818/840-9484 • 800/776-5972 • fax 818/840-9485 Lg-DMX/DC Indicators Each Lg-DMX/DC has twelve LED indicators. These are: 1) Outputs: Eight red LEDs show the status of each of the outputs. These dim and brighten as the each of the outputs is ramped up and down. 2) Test: One LED flashes whenever the Lg-DMX/DC is in one of the twelve ‘test’ modes.
Gilderfluke & Co.• 205 South Flower Street • Burbank, California 91502 • 818/840-9484 • 800/776-5972 • fax 818/840-9485 Lg-DMX/DC Connections There are only a small number of connections on each Lg-DMX/DC: 1) Power: The Lg-DMX/DC will run on any DC voltage from about 9 volts up to 24 volts. This power can come from batteries or a DC power supply that is run from line current. The incandescent lamps, LEDs, motors, or whatever you are controlling also run from the same power supply.
Gilderfluke & Co.• 205 South Flower Street • Burbank, California 91502 • 818/840-9484 • 800/776-5972 • fax 818/840-9485 3) ! Buffered DMX-512 Out: If DMX-512 needs to be run to additional downstream DMX-512 devices, the two standard DMX-512 connections (‘data +’ and ‘data -’) are attached to these terminals, along with (optionally) the wire shield. The DMX-512 received through the DMX-512 In/Out terminals will be buffered and retransmitted on these terminals.
Gilderfluke & Co.• 205 South Flower Street • Burbank, California 91502 • 818/840-9484 • 800/776-5972 • fax 818/840-9485 Lg-DMX/DC Configuration There are three rotary switches used set the DMX-512 address of the Ld-DMX/DC. You set the address by simply dialing in the DMX address of the first output to these three switches. You can use American-style (1-512) DMX addressing, or European-style (0-511) DMX-512 addressing, depending on the state of Dipswitch #7.
Gilderfluke & Co.• 205 South Flower Street • Burbank, California 91502 • 818/840-9484 • 800/776-5972 • fax 818/840-9485 7. ! Output under test goes to this level DipSwitch 5 Dipswitch 6 off off 100% on off 50% off on 25% on on Disables ALL ʻTestsʼ DipSwitch 7: European (0-511) or USA (1-512) DMX-512 Addresses On version 3.
Gilderfluke & Co.