EXAMPLE: to put AB/DR-3000 addressed at 55h into ECHO ALL mode: e 5 5
EXAMPLE: a 'START CARD# 00' command will echo:
t00
¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥
"f" Exit Echo All Mode:
This command takes all AB/DR-3000s in the system out of ECHO ALL MODE.
EXAMPLE: to take any and all AB/DR-3000s out of ECHO ALL mode: f
¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥
"g" Enter Echo Specific Mode:
This command puts all the AB/DR-3000s in the system into ECHO SPECIFIC MODE. When in this
mode, all AB/DR-3000 address-specific commands are echoed by the AB/DR-3000 addressed by the
command. This is the type of echo mode which best verifies the proper operation of all the AB/DR-
3000s.
EXAMPLE: to put AB/DR-3000 addressed at 55h into ECHO mode: g 5 5
EXAMPLE: a 'START CARD# 00' command will echo:
t00
¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥
"h" Exit Echo Specific Mode:
This command takes all AB/DR-3000s in the system out of ECHO SPECIFIC MODE.
EXAMPLE: to take any and all AB/DR-3000s out of ECHO mode: h
¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥
"i" (CARD#) Address Status Report:
This command responds with a stream of ASCII HEX data containing the current status of the AB/DR-
3000 specified by the CARD#
EXAMPLE: to poll the status for AB/DR-3000 addressed at 55h: i 5 5
¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥
"l" (CARD#) Switch Status:
This command responds with the following information for the AB/DR-3000 specified by the CARD#:
EXAMPLE: to poll the input switch status for AB/DR-3000 addressed at 55h: l 5 5
¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥
"m" (5AA5) (CARD#) Enter Configuration Mode:
This command puts the AB/DR-3000 specified by the CARD# into the configuration mode. All other
AB/DR-3000s in the system are prohibited from receiving any serial commands when there is even one
AB/DR-3000 in setup mode. They will not accept any serial commands until they hear the commands to
exit setup mode being sent to the one AB/DR-3000 which is in this mode. For details on the setup mode,
see the setup section of this manual.
EXAMPLE: to put AB/DR-3000 addressed at 00h into setup mode: m 5 A A 5 0 0
Note that only one AB/DR-3000 in the entire system is allowed to be in configuration mode at one
time. For this reason, if you try to put a AB/DR-3000 that doesnÕt exist into configuration mode you not
see a configuration screen from that nonexistent AB/DR-3000. All the other AB/DR-3000 in the system
won't listen to you until you take the nonexistent AB/DR-3000 out of configuration mode. To do this, type
GILDERFLUKE & CO. ¥ 205 SOUTH FLOWER ST. ¥ BURBANK, CALIF. 91502-2102 ¥ 818/840-9484 ¥ FAX818/840-9485