Datasheet

1/ Auxillary contact rating - 2A, 24Vdc Resistive load, 100,000 cycles. Minimum current is 1mA, 5V. The auxiliary contact
is mechanically linked to the main power contacts.
2
/ 50 Mohms after life.
3/ Contactor can operate up to 125°C in special cases - contact GIGAVAC for details.
GX12 B C
A
Coil Voltage
B = 12 Vdc with internal coil suppression
S = 12Vdc, Dual-Coil High Efficiency Option
with internal coil suppression
C = 24 Vdc with internal coil suppression
T = 24 Vdc, Dual-Coil High Efficiency Option
with internal coil suppression
F = 48 Vdc with internal coil suppression
H = 72 Vdc with internal coil suppression
J = 120 Vdc with internal coil suppression
K = 115 VAC, 50/60 Hz
L = 240 VAC, 50/60 Hz
Coil Termination
A = Flying leads, 38 cm (15 in)
B = Flying leads, 61 cm (24 in)
C = Flying leads, 122 cm (48 in)
Auxiliary Contact (same length as coil wire selection)
Blank = None
B = SPST, Normally Open