User Manual
Table Of Contents
- Gigaset C530 IP – Your perfect companion
- Overview of handset
- Safety precautions
- Getting started
- Checking the contents of the package
- Installing the base station and charging cradle
- Setting up the handset for use
- Connecting the base to a router (Internet)
- Setting up the phone – installation wizard
- Date and time
- Connecting the headset to the handset (optional)
- Activating/deactivating the handset
- Locking/unlocking the keypad
- Control key
- Display keys
- Menu guidance
- Message lists
- Entering numbers and text
- Making calls
- Using provider-specific functions (network services)
- Making cost-effective calls
- Adjusting the telephone settings
- Changing the display language
- Setting the display
- Activating/deactivating Auto Answer
- Changing the handsfree/earpiece volume
- Setting the earpiece profile
- Setting the handset ringtones
- Activating/deactivating music on hold
- Resetting a handset to the default settings
- Quick access to numbers and functions
- Setting the date and time manually
- Changing the system PIN
- Entering your own local area code
- Activating/deactivating music on hold
- Setting the IP address of the base in LAN
- Configuring VoIP connections
- Assigning send and receive connections to internal participants
- Updating the phone firmware
- Restarting the base
- Checking the base MAC address
- Restoring phone to default setting
- E-mail notifications
- Info Centre – continuous Internet access from your phone
- Network mailbox
- Multiple handsets
- Directories
- Local handset phonebook
- Phonebook entries
- Opening phonebook
- Creating a new entry
- Displaying/changing an entry
- Deleting an entry
- Setting the order of the phonebook entries
- Displaying the number of entries that are available in the phonebook
- Selecting a phonebook entry, searching in the phonebook
- Transferring an entry/phonebook to another handset
- Transferring a displayed number to the phonebook
- Transferring a number from the phonebook
- Online directories
- Using a private online directory
- Using the Gigaset.net phonebook
- Local handset phonebook
- Call lists
- ECO DECT
- Alarm clock
- Calendar
- Baby monitor
- Operating the telephone on a PABX
- Display icons
- Menu overview
- Configuring the phone via the Web configurator
- Connecting the PC with the telephone's Web configurator
- Establishing a connection via Gigaset config
- Logging in, setting the interface language
- Logging off
- Menu bar
- Navigation area
- Working area
- Buttons
- Help
- Opening web pages
- Connecting the base to the local network (LAN/router)
- Making security settings – managing certificates for TLS authentication
- Managing base connections; activating/deactivating connections
- Configuring/deleting VoIP connections
- Optimising voice quality for VoIP connections
- Assigning send and receive connections
- Activating the fixed line network connection as the fallback send connection
- User-defined dialling plans – specifying rules for telephony
- Access codes – activating dialling plans when connecting to a PABX
- Local area codes – activating dialling plans for local calls using VoIP
- Entering the network mailbox, enabling/disabling the network mailbox
- Making special settings for VoIP telephony
- Making settings for access to Internet services
- Deleting handset directories and downloading to/from the PC
- Changing the base settings, registering handsets
- Rebooting the device or restoring the factory settings
- Saving and restoring system settings
- Updating firmware for the base/restoring firmware updates, activating/ deactivating automatic updates
- Displaying the phone status
- 1. Changing the port numbers for SIP and RTP on your VoIP phone
- Exclusion of liability
- Care
- Contact with liquid
- Technical data
- Connecting the PC with the telephone's Web configurator
- FCC / ACTA Information
- Service (Customer Care)
- Glossary
- Accessories
- Mounting the charging cradle on the wall
- Index
91
Gigaset C530 IP / LUG - USA fr / A31008-XXXXX-XXXX-X-XX / add_features.fm / 3/25/15
Template Borneo, Version 1, 21.06.2012
ECO DECT
ECO DECT
La fonction ECO DECT permet de réduire la consommation électrique et les émissions.
Réduction de la puissance d'émission
En mode d'utilisation normale (valeur par défaut) :
Par défaut, la portée de l'appareil est maximale. De ce fait, une couverture radio optimale est
garantie. En mode veille, le combiné ne produit aucune émission. Seule la base assure le contact
avec le combiné en cas de signaux radio faibles. Au cours d'une communication, la puissance
d'émission s'adapte automatiquement à la distance entre la base et le combiné. Plus cette
distance est faible, et plus la puissance d'émission sera réduite.
Réduction de la portée et ainsi, diminution de 80 % de la puissance
d'émission
Dans de nombreuses habitations, bureaux etc., la portée maximale n'est pas nécessaire. Si le
réglage Portée Max. est désactivé, la puissance d'émission au cours des communications peut
être réduite de 80 % avec une portée diminuée par deux.
v
¤
Ï
¤ OK ¤ q ECO DECT ¤ OK ¤ q Portée Max. ¤ Modifier (³ =activé)
Icône d'affichage d'une portée réduite
¢ p. 98.
Réveil
Condition : Il est nécessaire d’avoir réglé au préalable la date et l’heure.
Activation/désactivation et réglage du réveil/de l'alarme
v ¤ É ¤ OK ¤ q Réveil/Alarme ¤ OK
Activation :
¤ r Act. / Dés.
Heure :
¤ Saisir une heure de réveil à 4 chiffres.
Période :
¤ Lundi-Vendredi / Quotidien
Volume :
¤ r Régler le volume.
Melodie:
¤ r Sélectionner la mélodie.
¤ Sauver
En mode veille, l'icône
¼et l'heure de réveil s'affichent.
Le réveil est indiqué à l'écran (
¢ p. 99) avec la mélodie sélectionnée. Il retentit pendant
60 secondes. Si aucune touche n'est actionnée, le réveil est répété deux fois toutes les cinq
minutes puis désactivé.
Pendant un appel, le réveil n’est signalé que par un bip court.