User's Manual
Communication Protocol
STX B CR
STX A CR
11
SECH CHKSUM
02 B 0d
02 A 0d
EXAMPLE
11
02 A3
8-3. GET AUTO POWER OFF TIME (HIGH BYTE) :
Get Parameter From Parameter Table Address : 11 h
Auto Power Off Time Period (High Byte) : 2*256/2 Seconds
Same 7-3. SET AUTO POWER OFF (HIGH BYTE)
STX B CR
STX A CR
19
SECH CHKSUM
02 B 0d
02 A 0d
EXAMPLE
19
FF CD
8-4. GET SOUND MODE :
Get Parameter From Parameter Table Address : 19 h
SOUND MODE : ENABLE
STX B CR
STX A CR
TRACK
SECH CHKSUM
02 B 0d
02 A 0d
EXAMPLE
30
FF CD
8-5. GET TRACK ACTIVE MODE :
Get Parameter From Parameter Table Address : 30 h
TRACK 1 ACTIVE MODE : ENABLE
TRACK
TRACK 1"30"
TRACK2"31"
TRACK3"32"
- 20 -