User Manual
Environmental requirements
Table 4 shows the humidity and temperature limits for the Anyplace Kiosk.
Table 4. Environmental requirements
Temperature (dry
bulb)
Maximum
temperature (wet
bulb) Relative humidity
Operating
5 to 40°C
(41° to 104° F)
27° C
(81° F)
8 to 80%
Power disconnected
0 to 52°C ( 32° to
126° F)
27° C
(81° F)
5 to 95%
Storage
0 to 60°C
(-32° to 140° F)
29° C
(84° F)
5 to 80%
Shipment
-40 to 60°C (-40° to
140° F)
29° C
(84° F)
5 to 100%
Small, variable-speed fans are used for processor and hard drive cooling when
temperatures exceed certain values. Ensure that the cooling vents are not blocked
by papers, signs, or other items.
Power usage
Table 5 shows the power consumption for the Anyplace Kiosk:
Table 5. Power usage
Description Amounts
Power consumption Off: 3W
Heat dissipation: Standby: 18W
On (idle/typical): 50W
On (maximum): 120W
Input voltage and current 100–240 V 50–60 Hz 1.4 A max: Input to power supply
Calling for service
When you call IBM for warranty information or service, be sure to have the following
information available:
v Machine type/model
v Serial number
You can locate this information on the lower-left edge at the rear of the machine.
Updated August, 2006
6 Anyplace Kiosk 4836/4838