User manual
BURNER Ø BYPASS 1/100 mm
Triple Crown 55
Oven 48
Grill 55
Gas burners for LPG G30 50 mbar
BURNER NORMAL
POWER kW
GAS RATE g/h REDUCED POWER
kW
INJECTOR
MARK 1/100 mm
Triple Crown 4.0 290.8 1.6 94
Rapid 3.0 218.1 0.72 77
Semi-rapid 2.0 145.4 0.43 60
Auxiliary 1.0 72.7 0.35 43
Oven 3.9 283.6 1.5 87
Grill 2.5 181.8 1.6 68
Gas connection
WARNING!
Before you connect the gas,
disconnect the appliance from the
electricity supply or switch off the
fuse in the fuse box. Close the
primary valve of the gas supply.
WARNING!
Use this appliance with the LPG
supply at a pressure of 50 mbar. If
you supply the appliance with a
lower pressure, the performance of
the appliance will be not
satisfactory.
The gas pipe in the appliance has two
endings. You can connect the gas supply to
either one of them. The pipe that is not used
must be clogged with the pipe closer, which
added to the appliance.
Use a fixed connections or use a flexible
stainless steel pipes in compliance with the
regulation in force. If you use flexible metallic
pipes, make sure they do not come in touch
with mobile parts and they are not squeezed.
WARNING!
When installation is complete,
make sure that the seal of each
pipe fitting does not leak. To check
the seal use a soap solution, not a
flame.
Flexible nonmetal pipes connection
If you have an easy access to the connection,
you can use a flexible pipe. The flexible pipe
must be tightly attached by clamps.
In installation always use the pipe holder and
the gasket. The flexible pipe can be applied
when:
21