Specification

7. ASTM A446-91: Standard Specication for Steel Sheet, Zinc Coated (Galvanized) by the Hot-Dip Process,
Structural (Physical) Quality.
8. ASTM B 117: Salt spray testing of coating 1000 Hrs.
9. ASTM G 23: Accelerated testing of coating 2000 hrs.
B. Manufacturers qualications:
1. Manufacturer has a minimum of ve years experience in manufacturing panels of this nature in a
permanent, stationary, indoor production facility utilizing industrial equipment.
2. Manufacturer has current nationally recognized model building code agency
product approvals for fastening design pressure capacities that meet projects
uplift resistance test requirements per (UL 580 Class 90 or higher).
3. Manufacturer has an approved independent quality assurance inspection program to validate certied
material and nished product specications.
4. Manufacturer has permanent ink marking on panels that identies the manufacturer, building code
approvals, and date of production for material traceability and warranty validation.
5. Manufacturers product is listed in the UL (Underwriters Laboratory) re resistant directory.
C. Installers qualications:
1. Installation of panels and accessories by installers with a minimum of two years experience in
panel projects of this nature.
1.03 Submittals
A. Shop drawings:
1. Submit complete shop drawings and erection details to Architect for review. Do not proceed with
manufacture prior to review of shop drawings. Do not use drawings prepared by Architect for shop
or erection drawings.
2. Shop drawings show methods of erection, elevations, and plans of roof panels, sections and
details, anticipated loads, ashings, roof curbs, vents, sealants, interfaces with all materials not
supplied and proposed identication of component parts and their nishes.
B. Samples:
1. Submit samples and color strips for all proposed nishes.
a. Submit one 12 in. long sample of panel.
b. Submit two 2 in round color chip samples in color selected by Architect.
C. Warranty(s):
1. Metal panel manufacturer, upon nal acceptance for project, furnish a warranty covering bare
metal against rupture, structural failure, and perforation due to normal atmospheric corrosion
exposure for a period of twenty-ve (25) years.
2. Covering panel nish against cracking, checking, blistering, peeling, aking, chipping, chalking,
and fading for a period of twenty-ve (40) years.
5V-CRIMP
A. Applicable standards, cont.: