Model LP700 Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual Contents: Installation Instructions: Pump Specifications: Exploded View: Parts, Kits, Torque: Repair Instructions: Dimensions: Warranty Information: Updated 12/98 page 2 page 3 page 4 page 5 page 6 page 7 back page
INSTALLATION INSTRUCTIONS Installation of the Giant Industries, Inc., pump is not a complicated procedure, but there are some basic steps common to all pumps. The following information is to be considered as a general outline for installation. If you have unique requirements, please contact Giant Industries, Inc. or your local distributor for assistance. 4. Use of a dampener is necessary to minimize pulsation at drive elements, plumbing, connections, and other system areas.
Specifications Model LP700 High-Pressure Plunger Pump Volume ..................................................................................................7.9 GPM Maximum Discharge Pressure .............................................................7250 PSI Maximum Inlet Pressure ......................................................................Up to 90 PSIG1 RPM .....................................................................................................1000 Plunger Diameter .............
LP700 EXPLODED VIEW 4
Model LP700 - PARTS LIST ITEM # 1 2 4 5 6 8 9 10 11 12 13 14 15 16 17 20 20A 20B 21 22 23 24 25 28 29 30 31 32 33 33A 35 PART # 07759 13000 06085 07104 07186 06086 01009 01010 01011 07109 07182 07111 07112 07113 07114 07116 07117 13001 07118 13242 13243 13340 13341 13232 06366 07779 07133 13418 13419 08087 13420 DESCRIPTION Crankcase Oil Filler Plug Assy Crankcase Cover O-Ring Oil Sight Glass Oil Dipstick Assy O-Ring Cylinder Screw Spring Ring Plug 1/2" Gasket Bearing Cover Radial Shaft Seal O-Ring Hexago
REPAIR INSTRUCTIONS - Model LP700 VALVE REPLACEMENT 1) Discharge Valves: Screw out 8 x hexagon screw (54), remove cover (51). Screw hexagon screw (54) into thread of plug (50) and pull out plug. Using a clipring pliers, remove spring tension cup (44A) and valve seat (44D). If necessary, use a dia 12 pull-out tool to remove valve seat. Cheack parts, and replace if worn. 2) Check O-rings (40/44E) and support rings (41/44F) and replace as necessary. 3) Tighten hexagon screws (54) TO 59 ft. lbs.
Model LP700 Dimensions 7 (inches)
GIANT INDUSTRIES LIMITED WARRANTY Giant Industries, Inc. pumps and accessories are warranted by the manufacturer to be free from defects in workmanship and material as follows: 1. For portable pressure washers and car wash applications, the discharge manifolds will never fail, period. If they ever fail, we will replace them free of charge.