Remote Control System Specification
Revision 7, 1 May 08 (Preliminary, not released for production)
1
Key Fob Transmitte
r
,
Giant Alarm System Co. Model JJ-RC-F with EV1527
Two buttons with one button designating up symbol
and the other a down symbol (see Remote Specifications)
2
Receiver Configuration;
Giant Alarm System Co. Model JJ-JS-06 with EV1527
Regeneration type frequency selection
- Nominal 12 V input to receiver..
- Operating temperature range: -5C to 75C
- Manufacture is to provide assurance of FCC approval
- Output rating:
12V 2 Amp minimum rating
12V 1 Amp maximum load
Operation Specification
Transmitter input Receiver output
To Moto
r
(transmitter has two buttons)
A
B
No buttons pushed 0 V 0
V
Both Buttons pushed 0 V 0
V
"A" button pushed and held + 12V - 12
V
"B" button pushed and held - 12
V
+ 12
V
(see
A
&
B
labels on picture below)
3 Receiver leads
6mm ring terminal +
6mm ring terminal
-
Terminal
Mating Tab
Altec Products Inc.
14050 Lincoln St. NE, Ham Lake MN 55304
Phone 763 785 9035 www.altecproducts.com
Fax 763 785 9084
5 A Fuse
Battery Input Leads:
120 cm (47") inch
leads to battery
Output leads to motor:
150 cm (59") lead length
20 Gage, two strand wire
Receiver
Red
Black
Transmitter Buttons
A B
Resister
Button "A" is Up, wire "A" is + and "B" -
Bottom "B" Is DOWN, wire "A" is - and "B" +
A B
Black Black with
wire white
stripe
Wire Specifications:
All wire is 20 gage (8mm) or larger, two
conductor, 105 deg C rated, minimum
insulation thickness of .50mm (.020 inch)
Two Conductor
(See layout
for button
detail
)
two push-on terminal receptacles to
fit 2.79mm wide x 0.51mm thick x
5.4mm long tab on motor supplied by
Altec