MODEL:PS-5000QAR Warning: This manual contains important safety and operating instruction. Please read it carefully before use. V0.20.
Specifications£ Data Model Continuous Power 5000W Peak Power 10000W Rated input Voltage 12VDC 24VDC Input Voltage Range 9.5~16VDC 19~32VDC 32VDC Over Voltage Shutdown 16VDC Low Voltage Shutdown 9.5VDC 19VDC Low Voltage Alarm 9.8VDC 19.
12. People with pacemakers should consult their physician(s) before using this product. Electromagnetic fields in close proximity to a pacemaker could cause interference to or failure of the pacemaker. 13. Keep the inverter well-ventilated. Do not place any objects on top of or next to the inverter or allow anything to cover the cooling fans; inverter will bel overheating, causing a potential fire hazard and/or damage to the inverter.
3. Do not mount the inverter upside down. 4. Allow 12 inches of space around the inverter to prevent objects from blocking the vents and to provide enough air to circulate. 5. Do not install the inverter in an environment with high dust, saw dust residue or other particles that may get sucked into the inverter increasing internal temperature. 6. There will be some electrical arcing or spark when the inverter connects with the battery. Combustible materials such as gasoline, alcohol, etc.
2. Battery Connection: Before you connect the battery cables, make sure the power switch is in the off position. Connect Red (+) battery cable to Red (+) inverter terminal. Connect Black (-) battery cable to Black (-) inverter terminal. Connect Red (+) battery cable to Red (+) battery terminal. Connect Black (-) battery cable to Black (-) battery terminal. Alligator clamp cables may be used but only to connect to the battery. Do not use clamps on inverter terminals.
Connection of big load For the appliances with a load more than the limit of AC socket ,please connect to the Hard wire Terminals (if have) ,make sure the ground terminal of inverter connected with ground terminal of appliance. H. SOFT START TECHNOLOGY The soft start technology built into this inverter protects the unit from delivering too much AC power at once by gradually increasing the AC voltage pushed out.
12. QUICK KNOWLEDGE ABOUT INVERTER ! Ensure Your Battery Size Is Big Enough And Voltage Is Correct. A. CORRECTLY CONNECTING THE INVERTER FOR FIRST USE. 1) Secure the provided Negative (black) DC cable connect to the Negative (-) bolt on the inverter, and the other end to the Negative (-) post on the battery. 2) Secure the provided Positive (Red) DC cable to the Positive (+) bolt on the inverter, and the other end to the Positive (+) post on the battery.