MODEL: PS-2200KAR
SPECIFICATIONS Data Item Continuous power 2200W Peak Power 4400W Rated input voltage 12V 24V Input voltage range 9.5~16VDC 19~32VDC Input over voltage shutdown 16V 32V Input low voltage shutdown 9.8V 19.6V 10.1V 20.
Remote controller box Positive of DC input(+) 4. INSTALLATION Ensure there is enough space for the installation, and the location should be meet the following requirements: 1. Water should not access the inverter. 2. The ambient temperature should be 32~104°F, and the preferred temperature is 5077°F. The lower the better in this range of ambient temperature. 3. Allow for 12 inches around the inverter for adequate air flow. 4. Do not mount the inverter upside down. 5.
2). Assemble the remote control box specification is 12V, 200Ah capacity and the load is 1000W. Take battery capacity 200Ah / 91.6 amps = 2.18 hours of run time if you fully deplete the battery. This is NOT recommended. Deep cycle batteries last longer when they are only depleted to 50% of capacity. 54mm 66mm 52.5mm 41mm 1) Fixed on the plane with an opening, four screws can be fixed directly on the four mounting holes of the remote control box.
7. USING THE POWER INVERTER 1. Check the output voltage and capacity of the battery. The battery (s) should match the voltage of the inverter and have enough capacity for the load. See Section E for more information. 2. Connect your inverter to your battery bank and do not to reverse the polarities of the connection. See Section F. 3. Press the power switch button on your inverter for 0.5 seconds and a green LED will light up indicating that the inverter is on. 4.
13. TROUBLESHOOTING TIPS 1. Do not use when the battery is charging. 2. Check the rated voltage of the battery and make sure that it is in the allowable range of the input voltage. 1. Cut off the load and allow to cool for 10 to 30 minutes. Restart after it reaches to normal temperature. 2. The load power is too large. Reduce the total load power to the range of rated power. 3. Avoid blocking the vent and improve the ventilation condition. 4. Reduce the ambient temperature. 1.