Instructions / Assembly
60
ACCESSORIES
Ghost Controls | www.GhostControls.com
INACTIVE — Opens circuit or has no connection.
ACTIVE — Input is shorted to COM or BATTERY NEGATIVE.
CYCLE INPUT (CYC):
Use this terminal for Ghost Controls Push Button (AXPB).
Active — Signal must go from INACTIVE then ACTIVE for the system to
recognize the input and respond accordingly.
EX: OPEN > STOP > CLOSE > STOP > OPEN >...
OPEN INPUT (OPEN):
Use this terminal for Ghost Controls Vehicle Detector (AXXV).
Active — OPENS gate to full open limit and prevents it from closing.
CLOSING-REVERSE INPUT (CLS-RVRS):
Use this terminal with photo eye beams or safety edge.
Active — Prevents gate from CLOSING or reversing to open limit if it was CLOSING.
OPENING-REVERSE INPUT (OPN-RVRS):
Use this terminal with photo eye beams or safety edge.
Active — Prevents gate from OPENING or reversing to close limit if it was OPENING.
MONITORED SAFETY DEVICES – PHOTO EYES (AXPE)
NOTE
Please refer to manufacturers manual or website for more detailed instructions on how to connect and use accessories
with your gate operator.
TERMINALS TO USE FOR REVERSE OPENING:
■ PWR = Switched 12 Volts (+)
■ MS–OP1 = Photos beam's output for 1st arm open-direction protection
■ MS-OP2 = Photos beam's output for 2nd arm open-direction protection
■ COM = Battery
IF THE BEAM IS BLOCKED OR DEVICE IS DISCONNECTED
■ Gate can not be open if idle
■ Gate will reverse direction and run to the closed position if it was opening
TERMINALS TO USE FOR REVERSE CLOSING:
■ PWR = Switched 12 Volts (+)
■ MS-CL1 = Photos beam's output for close-direction protection
■ COM = BATTERY NEGATIVE
IF THE BEAM IS BLOCKED OR DEVICE IS DISCONNECTED
■ Gate can not be open if idle
■ Gate will reverse direction and run to the open position if it was closing