Instructions / Assembly
53
PREPARING
Ghost Controls 2017 | www.GhostControls.com
DIP#4: DUAL (BI-PARTING) GATE OPENING SEQUENCE
The gate opening sequence for dual gate opener systems only is determined by DIP#4. This DIP switch does not apply to
single gate opener installations.
NOTE
The SECOND arm will always CLOSE first before the FIRST arm.
DIP Switch # OFF Position ON Position
4 Delay Open (Factory Default):
FIRST arm will open before the
SECOND arm.
Simultaneous Open: Both the FIRST arm and the SECOND arm
will simultaneously OPEN.
If Gate Lock is installed, the system will ignore this DIP switch
setting and default to delay open on the SECOND arm.
Not to be used with ZOMBIELOCK.
RECAP OF FACTORY SETTINGS FOR DIP SWITCHES
We recommend you mark your initial settings by placing a checkmark on this chart to refer to later if needed.
DIP Switch # OFF Position ON Position
1
Factory Default:
Pull-To-Open
Push-To-Open
2
Warning Disabled Factory Default: Warning Enabled
3
Factory Default:
SafeForce
®
Mode
Monitored Safety Mode
4
Factory Default:
Delay Open SECOND
Arm
Simultaneous Open