Full Product Manual

62
PUSHTOOPEN
©Ghost Controls
®
2023
I PRESS MY TRANSMITTER AND NOTHING HAPPENS NO BEEPS/NO MOVEMENT
The Number 3 dip switch (blue box of 4 switches on your system control board) is in the wrong position. It must be posi-
tioned to the left. (toward s.force). The only condition/reason to have it to the right is if you are using additional Ghost
Controls’ monitored external photo beams (AXPE).
I GET 5 BEEPS AND NO OPERATION.
Turn the system o and remove the 1st operator arm wires from the terminal. Check terminal and wire condition, replace
wires according to color code and turn the system back on. Test System.
I GET 7 BEEPS AND NO OPERATION.
This beep means no movement was detected from the 1st operator arm.
Replace the RED F1 10amp fuse on the system control board. Test System.
Turn the system o and remove the 1st. operator arm wires from the terminal. Check terminal and wire condition, replace
wires according to color code and turn the system back on. Test System.
I GET 8 BEEPS AND NO OPERATION.
This beep means no movement was detected from the 2nd operator arm.
Replace the RED F2 10amp fuse on the system control board. Test System.
Turn the system o and remove the 2nd operator arm wires from the terminal. Check terminal and wire condition, replace
wires according to color code and turn the system back on. Test System.
I AM HAVING TROUBLE GETTING THE GATE TO MOVE WITH THE JOGS BUTTONS DURING SETUP.
SINGLE PULL TO OPEN GATES.
Use a working remote to set your limit.
Activate the gate to close with the remote transmitter.
When the gate reaches the desired closed position press and release the remote transmitter button. This will stop the gate.
You may need to use the jog to fine tune the position.
Press and hold down the 1st set button until it beeps and release.
Activate the gate to open with the remote transmitter and the gate will return to full open and beep one time. It has learned
its closed limit position.
SINGLE PUSH TO OPEN GATES.
Use a working remote to set your limit.
Activate the gate to open with the remote transmitter.
When the gate reaches the desired open position press and release the remote transmitter button. This will stop the gate.
You may need to use the jog to fine tune the position.
Press and hold down the 1st set button until it beeps and release.
Activate the gate to close with the remote transmitter and the gate will return to the full close and beep one time. It has
learned its open limit position.
MY GATE PARTIALLY REOPENS AFTER CLOSING OR PARTIALLY RECLOSES AFTER OPENING.
This a limit adjustment issue or bracket placement. Please review your installation. Remember that on pull to open gates
the open gate position is determined by bracket placement with a fully retracted operator arm. For Push to open gates the
closed gate position is determined by bracket placement with a fully retracted operator arm.
LED Indicators on System Control Board
“POWER STATUS” LED GREEN = ON = transformer power present BLINKING = solar panel power present OFF = no
power present / not currently charging
“BATTERY CONDITION” LED YELLOW = ON = battery good BLINKING SLOWLY = low battery
BLINKING RAPID = fully charged OFF = Unit has been on longer than 1 minute (LED times out) or no battery detected.
STATUS LED Red = BLINKS ONCE = input change detected (exit sensor, wired push button activated, etc..)
BLINKS CONTINUOUSLY = blinks along with alarm codes to provide visual feedback. Also, it could mean a potential
accessory issue. Disconnect accessories connected to the “Hardwired Inputs” terminal and test system.
PROGRAMMING A NEW REMOTE CAUSES MY OTHER REMOTES TO STOP WORKING.
Only one remote transmitter is learned to the control board. See the inside cover of your control box for instructions. All
others must be cloned from that remote transmitter. See transmitter manual or ghostcontrols.com for more information.