Full Product Manual
55
PUSHTOOPEN
©Ghost Controls
®
2023
PROGRAMMING THE OPEN LIMIT: PUSHTOOPEN
The OPEN limit is when the operator is extended and the gate is in the OPEN position.
IMPORTANT
ONLY THE OPERATOR ARMS’ EXTENDED LIMIT IS ADJUSTABLE AND CAN BE SET WITH THE CONTROL
BOARD. THE ARMS’ RETRACTED POSITION IS FIXED AND IS NOT ELECTRONICALLY ADJUSTABLE.
THE CLOSED POSITION IS SET BY HARDWARE MOUNTING ONLY. Please refer to the hardware installation to
make sure the retracted position is properly set/installed.
Installation Type Retracted Position Extended Position
Push-To-Open Gate at the fully CLOSED position (not
electronically adjustable)
Gate at the OPEN position (electroni-
cally adjustable)
TURN THE CONTROL BOX ON
SETTING THE CLOSED LIMIT ON SINGLE GATES
A. Locate the 1st extended limit settings on the control board
and press and hold the JOG OPEN button for the 1st gate until the
gate reaches the desired OPEN position. The gate can move only
if pressure is maintained. Releasing the JOG button will stop the
gate immediately.
B. Both JOG OPEN or JOG CLOSE buttons are needed to ‘fine’ tune your desired OPEN position.
C
. Press and hold the 1st set limit button on the control panel until it beeps, then release.
D. Press the transmitter button to activate the gates and let the gate close fully you should hear a single beep.
When the gate reaches its CLOSED position, the control board will sound a single beep, confirming the OPEN
limit has been set.
E.
Confirm the newly programmed OPEN limit by pressing the remote transmitter button to activate the gate and
confirm the OPEN position has been set correctly. This limit is stored and remembered even when all of the power
sources are removed.
F.
Repeat if needed to change your desired OPEN position.
G. Test your system with the remote transmitter to make sure it opens and closes without errors.
1ST SET LIMIT SETTINGS