Full Product Manual
33
PULLTOOPEN
©Ghost Controls
®
2023
FOR DUAL GATES: SETTING THE CLOSED LIMITS
A. Locate the 2nd SET limit settings on the control board and press and
hold the JOG CLOSE button for the second gate until the gate reaches
the desired closed position. The gate can move only if pressure is
maintained. Releasing the JOG button will stop the gate
immediately. Once the 2nd gate is in the desired closed
position then repeat for the 1st gate with the 1st SET limit
settings JOG CLOSE button.
B. Both JOG OPEN or JOG CLOSE buttons are needed to ‘fine-tune’ your
desired CLOSED position.
C. Press and hold the 1st set limit button on the control panel until it beeps, then release.
Then Press and hold the 2nd set limit button until it beeps, then release
D. Press the transmitter button to activate the gates and let the gates open fully. You should hear a single beep.
When the gates reach its OPEN position, the control board will sound a single beep, confirming the CLOSED limit
has been set.
E. Confirm the newly
programmed CLOSED limit by pressing the remote transmitter button to activate the
gates and confirm the closed positions have been set correctly. This limit is stored and remembered even if
you lose power.
F. Repeat if needed
to change your desired CLOSED positions.
G. Test your system with the remote transmitter to make sure it opens and closes without errors.
1ST SET LIMIT SETTINGS
2ND SET LIMIT SETTINGS