Full Product Manual

26
PULLTOOPEN
©Ghost Controls
®
2023
WARNING
DO NOT SCREW THE OPERATOR ARM IN OR OUT TO ADJUST YOUR GATE POSITION. DOING SO
CAUSES THE SYSTEM TO NOT FUNCTION PROPERLY.
FRONT MOUNT GATE BRACKET INSTALLATION
TURN THE CONTROL BOX OFF
STEP 13A. FOR ROUND TUBE GATES ONLY attach the front mount using the tube gate
brackets.
A. Before assembling gate bracket make sure the (2) tube clamp brackets fit over the tubular gate bar. If not
they will need to be flared before continuing on to next step.
NOTE:
Tube gate brackets fit on gate tubes from 1 5/8" to 2"
B. Pre-assemble the tubular clamp brackets to the gate bracket by using the supplied gate and front mount
hardware. Insert (2) M8-65mm Hex Screws and (2) M8 Flat Washers through the Gate Mount Bracket holes
and attach to the Tubular Clamp Brackets and finish by inserting (2) M8- Flat Washers and (2) M8-Hex Nuts
to back of Clamp Brackets. GO TO STEP 14A.
STEP 13B. FOR FLAT OR DECORATIVE PANEL GATES attach front mount bracket to the
operator. The gate must remain in the desired open position.
OPEN THE GATE TO THE DESIRED OPEN POSITION
A. Temporarily assemble the front mount of the gate by inserting the supplied 10mm x 40mm clevis pin,
10mm I.D. nylon spacer, and clevis hairpin through the gate bracket. GO TO STEP 14B.