Instructions / Assembly

59
PROGRAMMING
Ghost Controls 2017 | www.GhostControls.com
NOTE
Only the arms’ extended limit is adjustable. The arms’ retracted position is FIXED and is NOT electronically adjustable.
The retracted position is set by hardware mounting only. Please refer to the hardware installation to make sure the
retracted position is properly set/installed.
Installation Type Retracted Position Extended Position Proceed To
Pull-To-Open Gate at the fully OPEN
position (not electronically
adjustable)
Gate at the CLOSED
position (electronically
adjustable)
Setting the Closed Position
on page 59
Push-To-Open Gate at the CLOSED posi-
tion (not electronically
adjustable)
Gate at the fully OPEN
position (electronically
adjustable)
Setting the Open Position
on page 60
SET THE CLOSED POSITION LIMIT FOR A PULL-TO-OPEN INSTALLATION
This is the most common installation. The CLOSED limit is when the operator is fully extended and the gate is in the
closed position.
1. Verify that the control box power switch is in the ON position. Turn on if necessary.
2. Move the gate or gates to the desired CLOSED position using the JOG CLOSE or
JOG OPEN buttons on the gate system control board. The JOG buttons on the
system control board (shown) can move the gate only if pressure is maintained,
releasing the button will stop the gate immediately. The JOG buttons can be used
as ‘fine’ adjustment of the CLOSED limit.
3. Once the gates are in the desired CLOSED position, press and hold the 1st SET
button until the alarm sounds, then release the button. If you have a dual gate then, press and hold the 2nd SET button
until the alarm sounds, then release the button. The unit is now in LEARN LIMIT mode.
4. Press the remote to run the gate to the fully OPEN position.
PROGRAMMING THE GATE
SYSTEM CONTROLLER
PULL-TO-OPEN AND PUSH-TO-OPEN APPLICATIONS