Full Product Manual
AXZLIM | REV 0217
©2016 GHOST CONTROLS
®
STEP 2: RUN THE ZOMBIELOCK WIRES FROM GATE LOCK TO THE CONTROL BOX
Run the wire across the cross section of the bar into the control box.
STEP 3: CONNECT THE WIRES FROM GATE LOCK TO CONTROL BOX
Connect the gate lock wires to the LOCK terminals on the control board. Once the red, black and blue wires are connected to
the terminals, tighten each of the screws so that the wires do not come loose.
■ Red wire connects to positive (+)
■ Black wire connects to negative (–)
■ Blue wire connects to S (S)
BLUE
BLACK
RED
STEP 4: CONTROLLER WILL AUTOMATICALLY DETECT THE LOCK WHEN SWITCH IS TURNED ON
■ Lock (if present) will be pulled (unlocked) for a few seconds at the closed position before opening. If lock is not completely pulled the
gate will not open to prevent damage to the gate and lock.
■ Lock will also be pulled (unlocked) near the closed limit position when it is closing to ensure a smooth and “soft” closing operation.
STEP 5: RECONNECT OPERATOR ARM TO FRONT GATE BRACKET WITH CLEVIS PIN AND HAIRCLIP
NOTE
MAKE SURE THE GATE LOCK CLOSES FIRMLY IN THE RECEIVER, SOME ADJUSTMENTS OF GATE
CLOSURE MAY BE NECESSARY. REFER TO YOUR GATE OPENER MANUAL FOR THE CLOSED POSITION
ADJUSTMENT.
GATE LOCK WIRE